TIMER-THERMOSTAT
MIRUS
DESCRIPTION
The MIRUS timer-thermostat is an electronic ambient thermostat that is easy to
use. It enables different temperatures to be assigned to various time periods.
Main Specifications:
Seven independent configurable programmes (one for each day of the week)
Large backlit display
Easy to programme off the base
Heating control
Two adjustable temperature levels: Comfort
and Savings .
Temperature adjustment from +5ºC to +35ºC
Temperature measurement and adjustment resolution: 0.1ºC.
Anti-icing temperature set at +5ºC (to prevent freezing).
Daily programmes: Configurable periods of 30 minutes.
INSTALLATION:
WARNING. The installation and assembly of the electrical apparatus shall be
undertaken by an authorised installer.
ALL POWER SHALL BE SWITCHED OFF BEFORE PROCEEDING WITH THE INSTALLATION.
THE POWER SHALL BE SWITCHED BACK ON ONLY WHEN THE EQUIPMENT IS FULLY
INSTALLED.
The apparatus is internally protected against interference.
INSTALLATION:
This is an electronic control device for independent installation on a wall or in a
mechanism box.
It is recommended that the apparatus be installed at a minimum height of 1.5
metres. The timer-thermostat installation shall be independent so that it is free from
obstacles and not affected by other devices or heat sources (sun, radiators, and
windows etc.)
When fixing the apparatus to the wall and in order to change the batteries, the
device mounting base must be released by applying pressure with a flat
screwdriver to the tab on the left side of the apparatus.
Fix the installation plate to the wall or mechanism box with the included crews.
CONNECTION:
Remove the terminal cover using a screwdriver and connect it according to the
following diagram:
HEATING
To control an installation via the meters, it is recommended that a suitable
capacitor be connected to its winding (0.1 μF 275 Vac).
INSERTING AND CHANGING BATTERIES:
The apparatus is fed by two LR6 (AA) 1.5 V alkaline batteries (not included). The
polarity indicated on the battery compartment must be respected. The batteries last
approximately one year.
When batteries are inserted for the first time, the screen is switched on and all the
display segments are shown and, after a few seconds, the timer-thermostat is
ready for operation.
When the MIRUS batteries have little power left and require changing, The “Lo
symbol is displayed at the bottom of the screen.
In order not to lose the current time, day of the week and temperatures
configuration, the battery change operation should be accomplished within fifteen
seconds. In any case, the fixed programming remains stored.
All used batteries shall be disposed of in a correct fashion. Respect the
environment.
SCREEN BACKLIGHTING
When any button is pressed on the MIRUS, the temporary backlighting comes on
to illuminate the display in order to easily programme the device.
SETTING THE TIME
The programming wheel is set to START and the button
is pressed and the day
of the week digit begins to flash. The or button is used to select the
corresponding day, the
button is pressed again to repeat the operation for the
hours and minutes in this order. Five seconds later automatic mode is entered with
the current time now set.
AUTOMATIC OPERATION (TIMER-THERMOSTAT)
When the programming wheel is set to the START position, the MIRUS will switch
the heating ON or OFF according to the current day programming. The TIMER will
show this programming in the display.
CONTROL TEMPERATURES
The factory-set temperatures are:
Savings
: 17 ºC
Comfort
: 20 ºC
These temperature values can be modified in START mode by pressing the button
corresponding to the temperature to be configured (Comfort
or Savings )
using the or button to change the value.
In order to determine the programmed type and temperature in the MIRUS at the
current time when in START mode, press either the
or button.
PRESET PROGRAMMES
The MIRUS Timer-Thermostat is factory-set with the following programming
Savings
: 00:00 to 06:00, 09:00 to 12:00, 15:00 to 17:00 and 22:00 to 00:00.
Comfort
: 06:00 to 09:00 to 12:00 to 15:00 and 17:00 to 22:00.
Saturdays and Sundays:
Savings
: 00:00 to 08:00 and 22:00 to 00:00.
Comfort
: 08:00 to 22:00.
MODIFYING PROGRAMMES
The programming wheel is set to the day to be programmed (for example, Monday
– 1, Tuesday – 2 etc.).
The temperature type is programmed in 30-minute periods beginning at 00:00. The
temperature type is defined by pressing the button corresponding to the desired
temperature (Comfort:
, Savings: , Off: ) . When the temperature is defined,
the following time period is selected. The
or button is used to move through
the time periods leaving the already assigned temperature.
In order to determine the programmed temperature, the display will show the start
time and the defined control temperature symbol will flash in the programme being
modified.
If there is no flashing symbol, it means that the time period being programmed the
timer-thermostat is Off, however, the anti-icing mode remains activated.
The programmed can be stored by moving the wheel to another day or to the
START position.
If, during programming, one minute passes without any button being pressed, the
screen will displayErr and the relay will de-energise until a button is pressed in
order to continue with the programming operation.
1
2
3
INSTALLATION PLATE
PROGRAMMING
WHEEL
RESET
COMFORT
TEMPERATURE
SELECTION
SAVINGS
TEMPERATURE
SELECTION
ON / OFF
SET DAY / TIME
INCREASE /
MOVE FORWARD
MANUAL
OPERATION
DECREASE /
MOVE BACK
INSTALLATION PLATE
INSTALLATION PLATE
5


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Orbis Mirus at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Orbis Mirus in the language / languages: English, German, French, Italian, Spanish as an attachment in your email.

The manual is 0,54 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info