OPERATING INSTRUCTIONS
INSTALLATION
WARNING: The installation and assembly of electrical equipment must be carried out
by an authorized installer.
- Open the top cover and insert the conductors thought the drillhole provided for this
purpose.
- Connect the conductors to the terminal strip following the scheme shown in figure 1.
Terminals 1 and 2 are for power supply and are marked L (live) and N (neutral).
Terminals 3 and 4 correspond to the timing circuit and terminals 5 and 6 to the early
warning circuit.
- Connect the earth wire to the terminal indicated for this purpose.
The appliance is internally protected from interference by means of a safety circuit.
Nevertheless, some especially strong electromagnetic fields may affect its operation.
Interferences may be avoided if the following installation instructions are followed:
- The equipment should not be installed close to inductive loads.
- It is advisable to provide a separate line for the power supply (if necessary provided
with a network filter).
- Inductive loads must be provided with interference suppressors (varistor, RC filter).
PROGRAMMING
IMPORTANT: PROGRAMMING MUST BE CARRIED OUT WITH THE APPLIANCE
DISCONNECTED FROM THE MAINS VOLTAGE.
All the programming is carried out by means of the device situated at the upper part of
the electronic circuit shown in figure 2.
The "CTM ELECTRÓNICO" is provided with 4 mini-switches known as SW1, SW2,
SW3 and SW4, two of which are rotary (SW1 and SW4) and the other two sliding.
Each one is responsible for the functions explained below.
MINIMUM NUMBER OF COINS
: Switch SW1 is used to indicate the number of coins
with which the operation of the timing circuit starts.
For instance, it is wished that the user of the installation has to insert 4 coins in order
for it to start operating. Turn SW1 until it indicates the number 4.
TIMING TIMES
: The timing time corresponding to each coin is established by the 5
first switches of SW2 or SW3. The 4 switches situated more to the left configure a
timing value and the fifth makes this value signify hours or minutes (ON = hours, OFF
= minutes). The value will be given by the combinations shown in the following table:
RESET: The RESET button initializes the programme of the "CTM ELECTRÓNICO"
and stores the present configuration. AFTER PROGRAMMING THE APPLIANCE THE
RESET BUTTON MUST BE PRESSED.
PAUSE: The pause function is used to temporarily stop timing without loss of memory.
The appliance enters this status when the pause terminals are disconnected and
remains in this status until their contacts become short-circuited again. This opening of
the circuit can be achieved either by means of a switch or by means of a potential-free
relay, see figure 3. IN ORDER TO AVOID MEMORY LOSS IN THE APPLIANCE IT
MUST BE RECEIVING POWER SUPPLY.
SPECIAL TIMING
: Switch SW4 indicates the number of coins by which the timing
passes from normal timing (configured in SW2) to special timing (configured in SW3).
To achieve maximum special timing it is necessary to insert all the coins one after
another. Setting SW4 to 0 deactivates special timing.
EARLY WARNING
: Switch 6 of SW3 is used to select the duration of the early warning
activated prior to the end of timing.
ON - Long early warning. 4 minutes before the end of the timing the early warning
circuit will be connected for 30 seconds.
OFF - Short early warning. 30 seconds before the end of the timing the early
warning circuit will be connected for 10 seconds.
ADJUSTMENT OF TYPE OF COIN:
The type of coins to be used can be modified by the user following these steps:
- Change the coin insert slot (External plate)
- Loosen the screws in order to be able to move parts A and B (see fig. 4).
- Move parts A and B until the desired coin diameter is obtained
- Fasten to screws to fix the desired position.
COIN OR TOKEN OPERATED TIME METER CTME
DISPLAY
COIN BOX
PROTECTIVE
CASING
COIN
INTER
SLOT
123456
LN
TEMPORIZ ACIÓN
PREAVISO
CABLE APERTURE
EARTH CONNECTI
O
CONNECTION
STRIP
FIXTURE
DRILLHOLES
FIG. 1
SW7
SW1 SW4
0
1
2
3
4
5
6
7
8
9
0
1
2
3
4
5
6
7
8
9
SW2 SW3
ON
123456
ON
123456
RESET (SW7)
Nº OF COINS (SW1)
NORMAL TIMING (SW2)
(SEE TABLE)
HOURS
POSITION
HOURS
POSITION
SHORT EARLY
WARNING POSITION
LONG EARLY
WARNING POSITION
NORMAL TIMING (SW3)
(SEE TABLE)
Nº OF COINS FOR
SPECIAL TIMING (SW4
FIG. 2
MINUTES
POSITION
MINUTES
POSITION
UNUSED
POSITION
VALUE
OFF
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
1
2
3
4
5
6
7
8
POSITION
VALUE
OFF
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
9
10
15
20
30
45
90
150
OFF OFF OFF
OFF OFF OFF
OFF OFF OFF
OFF OFF
OFF OFF OFF
OFF OFF
OFF OFF
OFF
OFF OFF
OFF OFF
OFF OFF
OFF
OFF OFF
OFF
OFF
R3
D5
D2
C7
D6
SW7
IC7
R2
C13
D3
SW1
C5
C4
C1
C2
BR1
SW5
C9
SW4
D7
X1
IC2
ARR1
C3
D1
F1
C11
C10
C8
R1
L2L1
IC1
D4
REL1
IC6
C6
SW3
SW2
IC8
IC3
D8
IC4
C12
TR1
N. MINIMO
T.ESPECIAL
N.MONEDAS
JP1
DE MONEDAS
T.ESPECIAL
DISPLAY1
T.NORMAL
PREAV.
REL2
FIG. 3
POTENTIAL - FREE
CONTACT
PAUSE
TERMINALS
SLIDING GUIDE
PIVOTS
FIXING SCREWS
(A)
(B)
COIN DIAMETER
FIXING SCREW
C
O
I
N
D
I
A
M
E
T
E
R
FIG. 4
3


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Orbis CTME at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Orbis CTME in the language / languages: English, Spanish as an attachment in your email.

The manual is 0,06 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info