704057
36
Zoom out
Zoom in
Previous page
1/48
Next page
32
7. Specifications
Product category Electronic Sphygmomanometers
Product description Automatic Upper Arm Blood Pressure Monitor
Model (code) MIT5s Connect (HEM-7280T-E)
Display LCD digital display
Measurement method Oscillometric method
Transmission method Bluetooth Version 4.0 (Low Energy support)
Wireless communication Frequency range: 2.4GHz (2400 - 2483.5 MHz)
Modulation: GFSK
Effective radiated power: <20 dBm
Measurement range Pressure: 0 to 299 mmHg
Blood pressure measurement range 20 to 280 mmHg
Pulse measurement range 40 to 180 beats/min.
Accuracy Pressure: ±3mmHg
Pulse: ± 5% of display reading
Inflation Fuzzy-logic controlled by electric pump
Deflation Automatic pressure release valve
Memory 100 measurements with date and time for each user (1 and 2)
Rating DC6V 4W
Operation Mode Continuous operation
Power source 4 “AA” batteries 1.5V or optional AC adapter
(INPUT AC100-240V 50-60Hz 0.12-0.065A)
Durable period
(Service life)
Monitor: 5 years
Cuff: 1 year
Optional AC adapter: 5 years
Battery life Approximately 1000 measurements
(using new alkaline batteries, operating temperature and humidity 23°C, 65% RH, cuff
circumference 25 cm, max pressure170 mmHg)
Applied part Type BF (Cuff)
Protection against electric shock Internally powered ME equipment (When using only the batteries)
Class II ME equipment (Optional AC adapter)
Operating conditions +10°C to +40°C (50 to 104°F) / 15% to 90% RH (non-condensing) / 700 to 1060 hPa
Storage / Transport conditions -20°C to +60°C (-4 to 140°F) / 10% to 95% RH (non-condensing) / 700 to 1060 hPa
IP classification Monitor: IP20
Optional AC adapter (HHP-CM01): IP21
Optional AC adapter (HHP-BFH01): IP22
Weight Monitor: Approximately 364 g without batteries
Arm cuff: Approximately 170 g
Outer dimensions Monitor: Approximately 114 (w) mm × 85 (h) mm × 139 (l) mm
Arm cuff: Approximately 145 mm × 594 mm
36


Need help? Post your question in this forum.

Forumrules
1

Forum

omron-mit5s-connect----hem-7280t-e

Reset search

  • Model HEM-7280T cant export data as a pdf file as I have previously done Submitted on 1-10-2022 at 05:41

    Reply Report abuse


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Omron MIT5s Connect - HEM-7280T-E at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Omron MIT5s Connect - HEM-7280T-E in the language / languages: English as an attachment in your email.

The manual is 1,3 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Omron MIT5s Connect - HEM-7280T-E

Omron MIT5s Connect - HEM-7280T-E User Manual - German - 48 pages

Omron MIT5s Connect - HEM-7280T-E User Manual - Dutch - 48 pages

Omron MIT5s Connect - HEM-7280T-E User Manual - French - 48 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info