504878
17
Zoom out
Zoom in
Previous page
1/26
Next page
17
Wrap the arm cuff over the
patients arm.
1.
Set the MODE Selector to
“AVG.”.
3.
ON/OFF
A
V
G
.
/
1
s
t
/
2
n
d
/
3
r
d
D
E
F
L
A
T
I
O
N
START
STOP
HIDE
P
-
SET
100
AUTO
140 180
220
260
280
MODE
AVG.
MANU.
CHECK
SINGLE
Push the START Button to start
the measurement.
Set the unit to the start time of
the rst measurement, then the
unit starts measurement auto-
matically.
After displaying the results of
rst measurement, the unit will
measure blood pressure in the
set number of times automati-
cally by taking an interval.
For the setting of the number of
measurements, the waiting time
before start of measurement,
and the interval time, refer to
Page 7.
5.
ON/OFF
A
V
G
.
/
1
s
t
/
2
n
d
/
3
r
d
D
E
F
L
A
T
I
O
N
START
STOP
HIDE
P
-
SET
100
AUTO
140 180
220
260
280
MODE
AVG.
MANU.
CHECK
SINGLE
Push the ON/OFF (power)
Button to turn off the power.
7.
ON/OFF
A
V
G
.
/
1
s
t
/
2
n
d
/
3
r
d
D
E
F
L
A
T
I
O
N
START
STOP
HIDE
P
-
SET
100
AUTO
140 180
220
260
280
MODE
AVG .
MANU.
CHECK
SINGLE
Push the ON/OFF (power)
Button to turn on the power.
2.
ON/OFF
A
V
G
.
/
1
s
t
/
2
n
d
/
3
r
d
D
E
F
L
A
T
I
O
N
START
STOP
HIDE
P
-
SET
100
AUTO
140 180
220
260
280
MODE
AVG.
MANU.
CHECK
SINGLE
Set the P-SET (pressure set-
ting) Volume to “AUTO” or the
target in ation value.
When setting the P-SET to
AUTO”, turn the Volume coun-
terclockwise as far as it goes
until you can hear the click
sound.
When the systolic pressure is
expected to exceed 220 mmHg,
proper in ation may not be pos-
sible in “AUTO setting.
Set the target in ation value to
30 to 40 mmHg higher than the
expected systolic pressure.
4.
ON/OFF
A
V
G
.
/
1
s
t
/
2
n
d
/
3
r
d
D
E
F
L
A
T
I
O
N
START
STOP
HIDE
P
-
SET
100
AUTO
140 180
220
260
280
MODE
AVG.
MANU.
CHECK
SINGLE
Measured results are
displayed.
After the measurement is
completed, average values are
displayed.
Each time a DEFLATION
(de ation control) Button is
pushed, the measurement
results for each time are
displayed.
6.
HIDE
BPM
mmHg
PULSE
SYS
mmHg
DIA
How to Measure Blood Pressure (in AVG. Mode)
To stop the measurement during the measurement:
Push the STOP Button.
To start the stopped measurement again:
Push the START Button.
17


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Omron HEM-907 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Omron HEM-907 in the language / languages: English as an attachment in your email.

The manual is 3,28 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Omron HEM-907

Omron HEM-907 User Manual - German - 26 pages

Omron HEM-907 User Manual - Dutch - 26 pages

Omron HEM-907 User Manual - Dutch - 23 pages

Omron HEM-907 User Manual - Italian - 26 pages

Omron HEM-907 User Manual - Spanish - 26 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info