Installing the stove
The floor on which the stove is installed must be even and
horizontal. The stove may only be installed on an adequate
load-bearing floor. The stove can be stood on a metal floor
sheet or glass sheet to protect the flooring.
If the flooring or carpet is inflammable, a stable and non-
combustible spark protection plate must be used. This
must extend 50 cm to the front and 30 cm to each side
beyond the edge of the combustion chamber opening.
Under the stove no spark protection plate is required.
Assembly sequence
If intended, install the OEC or OEC SMART1.
Install the side cladding.
The Ø150mm stovepipe connection can be installed at
the top or rear. The stove is supplied ready for connec-
tion from above. If you wish to connect it at the rear, the
following steps must be carried out to make the neces-
sary modifications:
- Break out the cover in the back panel.
- Replace the connector sleeve and the sealing cover.
Decide where the stove is to be installed. There must be
no objects made of combustible materials within a dis-
tance of 80 cm of the stove’s radiation area, measured
from the combustion chamber’s inspection glass, nor
may any be placed within this area subsequently.
Depending on the installation position of the stove in
front of walls that need to be protected (flammable or
load-bearing), the following distances from walls need
to be observed in accordance with the position of the
combustion chamber door to the wall / side panel or
the back panel (see schematic diagram).
When not dealing with walls that need to be protect-
ed, you merely need to observe a minimum distance of
approx. 5 cm to allow for proper heat dissipation.
Install the pipe lining (provided on site) in the chimney.
The connection height can be individually specified for
a top stovepipe connection, however should not exceed
1.5 m from the connector sleeve. For the rear stovepipe
connection heights please refer the Technical Data“
chapter. No combustible material is permitted within a
radius of 20 cm around the stove pipe.
Connect the stovepipe at both connection points with
stove putty so that the stove pipe is permanently sealed.
Push the stove onto its planned position and orient it so
that the stovepipe fits into the pipe lining.
The stovepipe connections must be tight. The stove-
pipe must not protrude into the chimney.
Bear in mind that on partition walls in accordance with
test specication EN 13240 the temperature of 85°C
can be reached, and with light wallpaper or similar
combustible construction materials this can result in
colour changes.
Dimensions in cm
Dimensions in cm
Stove installed straight in the corner
Stove installed diagonally in corner
Dimensions in cm
40
40
20
20
20
110
14


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Olsberg Salado Compact at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Olsberg Salado Compact in the language / languages: English, German, French as an attachment in your email.

The manual is 1,33 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info