Technical Data
Nominal thermal output ................................. 5,0 kW
Room heat output .......................................... 5,0 kW
Height to middle of the connector pipe
with the connection is at the back ............. 1243 mm
Height to the top edge of connector pipe
with the connection at the top .................... 1379 mm
Connection pipe ...................................... Ø 150 mm
max. Weight................................................... 189 kg
Height to middle
of combustion air connection ....................... 360 mm
Connection combustion air ...................... Ø 125 mm
Operating mode ........................ Intermitting burning
Regulations to be observed
Local and building law regulations
The stove must be installed by a professional and
connected to the chimney. The specic national reg-
ulations for safe installation of the connector must be
complied with. The connecting piece used must pos-
sess an opening for cleaning.
The stove must be regularly checked by a
professional.
The stove has national technical approval from the
Deutsches Institut für Bautechnik (DIBt) (German
Institute for Civil Engineering) for room-air independ-
ent operation.
Due to its general technical approval, the stove
Fuego Compact can be used simultaneously with
an approved ventilation system without addition-
al safety device.
The heating stove’s re door is selfclosing; it is there-
fore approved for connection to chimneys with multiple
connections.
Foreword
This stove is a top quality modern heating technology
product.
A large degree of user comfort and high fuel utilisa-
tion enable it to be used as high quality space heat-
ing, without having to do without the cosy atmosphere
of an open re.
Proper installation and correct handling and care are
indispensable for problem-free operation and a long
service life. Please therefore observe all the informa-
tion given in these instructions. We are convinced that
you will then derive a great deal of pleasure from this
stove. Please keep these instructions in a safe place
so that you can read through them at the start of each
heating period.
Should you nd any transport damage, please report it
to your supplier immediately as otherwise it will not be
possible to correct the damage free of charge.
Stove Fuego Compact 23/605
Table of Contents
Foreword ................................................................. 10
Technical Data ........................................................ 10
Regulations to be observed .................................. 10
Chimney design ...................................................... 11
Combustion air supply ........................................... 11
External combustion air connection...........................11
Installing the stove ................................................. 11
Assembly sequence ..................................................11
Operation ................................................................. 12
Permissible fuels ...................................................... 12
Please note before heating for the rst time ............. 12
Igniting ...................................................................... 12
Combustion air slide valve........................................ 13
Regulation of combustion air .................................... 13
Fire grate .................................................................. 13
Wood storage compartment ..................................... 13
Heating ..................................................................... 14
Heating during the transition period.......................... 14
Natural stone cladding ........................................... 14
Special information ................................................ 14
Cleaning .................................................................. 14
Measuring negative pressure in the combustion
chamber................................................................... 15
Replacement parts ................................................. 15
What to do if ...? ...................................................... 15
10


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Olsberg Fuego Compact at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Olsberg Fuego Compact in the language / languages: English, German, Dutch, French, Spanish as an attachment in your email.

The manual is 1.8 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info