812264
94
Zoom out
Zoom in
Previous page
1/160
Next page
LEVANA 2.0 6 kW
LEVANA 2.0 8 kW
LEVANA AQUA 2.0
ARINA 2.0
INARA 2.0
EN
6 Product data sheet
Stove product data sheet
Technical Documentation according to Regulation (EU) 2015/1185 for solid fuel local space heaters (with additional parameter of Technical Documentation according to Regulation (EU)2015/1186)
Model identi er LEVANA 2.0, 43-247
Manufacturer
| Adress Olsberg GmbH |
Hüttenstraße 38
|
59939 Olsberg
|
Deutschland
Test reports PL-20050-3-P
Test laboratory TU Wien, Getreidemarkt 9/166, A-1060 Wien
Harmonized Standards EN 14785:2006-09 /EN 16510-1:2018-07 /EN
16510-2-6:2014-07
Other technical standards and speci cations CEN/TS 15883:2010
Indirect heating function [yes / no] nein
Direct heat output 8,7 kW
Indirect heat output
1
0,0 kW
Characteristics when operating with the preferred fuel
Seasonal space heating energy e ciency ηs [%]: 81,1 %
Energy e ciency index (EEI): 122,2
Energy e ciency class A+
Fuel Preferred
fuel (only
one):
2
:
Other suitable
fuel (s)
3
:
ηs
[x%]:
Emissions at nominal
heat output
Emissions at minimum
heat output
4
PM OGC CO NOx PM OGC CO NOx
[x] mg/Nm3 (13 % O2) [x] mg/Nm3 (13 % O2)
Wood logs, moisture content ≤ 25 % no no
Compressed wood, moisture content < 12 % yes yes 80,6 19 4 214 126
Lignite briquettes no no
Other fuels
5
no no
Speci cation Item Value Unit
nominal heat output P
nom
8,0 kW
minimum heat output (partial load heat output according to standard) P
min
0,0 kW
Auxiliary power consumption at nominal heat output el
max
0,031 kW
Auxiliary power consumption at minimum heat output el
min
0,000 kW
Auxiliary power consumption in standby mode el
SB
0,003 kW
Permanent pilot  ame power requirement (if applicable) P
pilot
N. A. kW
Speci c precautions for assembly, installation or maintenance
Fire protection and safety distances such as distances to combus-
tible building materials, among others, must be observed under all
circumstances!
A su cient supply of combustion air for the appliance must be gua-
ranteed at all times. Air-suction systems can interfere with the com-
bustion air supply!
Fuel e ciency at nominal heat output (Based on the net calori c value (NCV) ηth,nom 91,4 %
Fuel e ciency at minimum heat output (Based on the net calori c value (NCV) ηth,min 0,0 %
Type of heat output/room temperature control (select one):
Single-stage heat output, no room temperature control no
two or more manual stages, no room temperature control no
with mechanic thermostat room tem-perature control no
with electronic room temperature con-trol no
with electronic room temperature con-trol plus day timer no
with electronic room temperature con-trol plus week timer no
Other control options (multiple selection possible)
room temperature control, with pres-ence detection no
room temperature control, with open window detection no
with distance control option no
1 No entry is made for  replaces without water-bearing components.
2 Values for the annual e ciency and emissions are to be given here for the preferred fuel.
3 Values for annual fuel e ciency and emissions are to be given here for all other, other suitable fuels.
4 Corresponds to the partial load heat output according to EN 16510
5
Wood-like biomass, non-wood-like biomass, anthracite and dry steam coal, hard coal coke, low-temperature coke, bituminous coal, peat briquettes, briquettes made
from a mixture of fossil fuels, other fossil fuels, briquettes made from a mixture of biomass and fossil fuels, other mixture of biomass and solid fuels
Product data sheet
94
We reserve the right to make technical changes
78-4643-2481_R6_LEVANA 2.0_ARINA 2.0_INARA 2.0_DE-EN-FR.indd 9478-4643-2481_R6_LEVANA 2.0_ARINA 2.0_INARA 2.0_DE-EN-FR.indd 94 11.04.2023 14:42:0111.04.2023 14:42:01
94


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Olsberg ARINA 2.0 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Olsberg ARINA 2.0 in the language / languages: English, German, French as an attachment in your email.

The manual is 34.97 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info