2 INSTALLATION
2.1 INSTALLATION MODES
To obtain the best results and optimum performance, follow the instructions for correct installation provided in this manual. Failure
to follow the instructions and apply the rules indicated may cause malfunction of the appliance and relieves the manufacturer,
OLIMPIA SPLENDID of any form of guarantee and liability for damages to persons, animals or property.
The electrical system must comply with the regulations and rating data in the technical sheet, with good grounding.
2.1.1 Size and specifications of the room in which to install the air conditioner
Before installing the air conditioner, it is essential to make an accurate calculation of the heat load in summer (and cold load in winter
for models with heating pump) at the site of installation.
The more accurate this calculation is made the better the air conditioner will be able to do its job.
When executing the calculations, refer directly to the prevailing standards.
For particularly important applications, we recommend contacting expert heating engineers.
The user should try to limit high heat loads as much as possible as follows: glass doors and windows exposed to many hours
of sunlight should be fitted on the inside with curtains or, even better, on the outside with coverings such as Venetian blinds,
verandahs, refractive film, etc.). The air-conditioned room must remain closed as long as possible.
Halogen spotlights or other electrical equipment with high power consumption should not be used in the room (toasters, steam
irons, hot plates for cooking, etc.).
2.2 CHOOSING THE POSITION OF THE UNIT
The position for installing the unit, to obtain best performance and avoid breakdowns or hazards, must have the following requisites
(fig. 3):
- The height of the unit's lower edge from the floor should be at least 100 mm if fixed to the wall in the lowest position.
- If fixed to the wall in the highest position, it should be at least 80 mm from the ceiling.
- The wall on which the inside unit is installed must be sturdy and able to withstand its weight.
- It must be possible to leave room around the unit for any maintenance operations that may be necessary.
- Nothing should be in the way of the air that needs to circulate both on the top air-intake (curtains, plants, furniture) and at the
front where the air exits. This could cause air swirls that would inhibit the working efficiency of the unit.
The air conditioner must be installed on a wall that communicates with the outside.
CAUTION: after determining the best place for installation as described above, check for the absence of other
structures or systems (beams, piers, pipes, wires, etc.) at the points where the holes are to be drilled, which
would prevent drilling the holes required to install the unit.
Check again to make sure there are no obstacles to air circulation through the holes to be drilled due to plants
and their leaves, slats or panelling, blinds, gratings or grids too dense, etc.).
WARNINGS (fig. 4):
- it should not be placed under curtains;
- do not spray water or other liquids of any kind directly on the unit;
- it should not be installed in a position where the air flow can directly strike people in the whereabouts.
- never force the opening of the airflow flap;
- do not place bottles, cans, clothing, flowers or any other object that may damage the internal organs on the air aspiration grill
or anything that may even partially obstruct the grill itself;
- it should not be directly over another appliance (television set, radio, refrigerator, etc.), or over a source of heat.
2.3 UNIT ASSEMBLY
2.3.1 Warning
The maximum length allowed for pipes is 1 m. The pipes must be smooth on the inside, and with a diameter of 202 mm. Pipes cannot
be curved or bent.
It is necessary to use the grilles provided, or grilles which keep the same features.
2.3.2 Drilling the wall
Install the unit by drilling two holes (diameter of either 162 mm or 202 mm) in the wall as indicated in the drilling template. The 202-
mm holes will ensure best performance and utmost noiselessness.
The UNICO unit may be installed in lieu of a UNICO SKY or UNICO STAR unit without changing the position of the existing holes,
with the exception of the small hole for condensate drainage. In this case, in order not to penalize performance, remove the insulating
material from the air outlet pipe. Drill the wall using the proper tools to facilitate your job and prevent excess damage or disturbance
to your client. The best tools for drilling large holes in walls are special drills called core borers with very high twisting torque and
adjustable rotating speed depending on the diameter of the hole to be drilled.
2
Downloaded from AC-Manual.com Manuals
29


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Olimpia Splendid Unico at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Olimpia Splendid Unico in the language / languages: English, German, French, Italian, Spanish as an attachment in your email.

The manual is 11,47 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Olimpia Splendid Unico

Olimpia Splendid Unico User Manual - Dutch - 31 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info