2.6 - SELECTION OF POSITION FOR OUTSIDE UNIT
To obtain the best operating performance and prevent faults or hazardous conditions, the position of outdoor
unit installation must meet the following requirements:
a 
b
c                

d
e. The outside unit must be installed perfectly level (check with a bubble level).
Note: If the outdoor unit must be installed on the wall or roof, it is necessary to use the relevant kit (optional)
For assembly, follow the relative instructions, attached to the kit packaging, scrupulously.
f. The unit must not be in a position that obstructs the passage of persons or animals.
g. The unit should not be installed downwind of chimneys discharging burnt gas or subject to emissions of
fumes, oily or corrosive gasses.
h. It should be possible to discharge the condensation produced.
i. Take the air conditioner weight into account and select a place where noise and vibration will not be an
issue.
l. Select a place so that the warm air and noise from the air conditioner do not disturb neighbors.
m
Position the outdoor unit on a raised surface (wall), with height above the foreseeable maximum amount
of snowfall, since:
 
and cause damage to the electric components.
 

n
The support base must have good drainage of the water and prevent the possible accumulation of dirt


No interventions are required when positioned on a balcony, since there is already enough slope for the

o

dimensions and capacity suitable for the weight of the machine (on request).

regular operation.
p. Make sure that there is the minimum space around the outdoor unit necessary to guarantee correct

2.6.1 - Heat pump appliances.
 During operation in heating mode, condensate is produced in the outdoor unit due to defrosting, which
must be able to run-off freely to prevent stagnation.
 

 In the case of installation on a balcony or terrace, it must be possible to position a recipient under the

gutter.
-
-
73


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Olimpia Splendid NEXYA S4 E DUAL INVERTER 21 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Olimpia Splendid NEXYA S4 E DUAL INVERTER 21 in the language / languages: English, German, Dutch, French, Italian, Portuguese, Spanish as an attachment in your email.

The manual is 26,21 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info