NL - 24

plakken, dat zich op het vulpunt bevindt.



installatie, het onderhoud of de verwijdering.
 
mogelijk worden opgespoord en gerepareerd.
De assistentie mag op dit product UITSLUITEND door bevoegd personeel worden
uitgevoerd.

-
selijke voorschriften in acht worden genomen .bv. bij handmatige verplaatsing van
het product of bij het vullen met gas.
2.6.7 - Aansluiting van de condensafvoerlijn
Sluit een afwateringsbuis van geschikte lengte aan met de condensafvoerlijn van de binnenunit en blokkeer
met een klem.
De buis in de kabelgoot plaatsen, evenwijdig met de buizen van de installatie, en hem eraan bevestigen
met een klem.
De klemmen niet te veel aanspannen om de isolering van de buizen niet te bescha-
digen en de afwateringsbuis niet te smoren.
Voer de condens indien mogelijk af in de goot voor regenwater.
Als de afvoerleiding in een rioleringssysteem terechtkomt, is een bocht nodig in
de buis voor een sifon (afb. 25) om de verspreiding van onaangename geuren in
de omgeving te voorkomen.
De bocht van het sifon mag nooit lager staan dan 1500 mm van de onderste rand
van het apparaat (afb.25).
Bij afwatering in een recipiënt (afb. 26) mag deze nooit gesloten zijn om schadelijke
tegendruk te vermijden en de buis mag nooit het vloeistofniveau in de recipiënt
bereiken.
Controleer of de condensvloeistof door de betreffende buis wegstroomt door heel
langzaam ongeveer 1/2 liter water in de verzamelbak van de binnenunit te gieten
(afb. 27).
278


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Olimpia Splendid NEXYA S4 E - PENTA INVERTER 42 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Olimpia Splendid NEXYA S4 E - PENTA INVERTER 42 in the language / languages: English, German, Dutch, French, Italian, Portuguese, Spanish as an attachment in your email.

The manual is 21,54 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info