ENTERING SETTINGS -SET MODE #1
TO SET - FO2 (while in the Surface Mode)
Factory set for Air, FO2 can also be set to values between 21
and 50% in increments of 1%.
• Press Both buttons simultaneously, release when SET: 1
appears.
• Press and release the Advance (Front) button, FO2 ap-
pears with the value flashing (Fig. 19).
• Press and release the Side (Select) button repeatedly to
increase the FO2 value from 21 to 50% in increments of
1%, then display AIR again; - or - Press and hold the Side
(Select) button to scroll from AIR to 32%, then press and
hold again to scroll from 32 to 50%, then AIR.
• For each FO2 value that appears, the display indicates the
Maximum Depth that can be achieved for a PO2 of 1.60
ATA (Fig. 20), or the setting selected by the user. If FO2 is
set for Air, no value is displayed.
• Press the Advance (Front) button to accept the setting and
advance to Set Depth Alarm, or press and hold Both
buttons for 2 seconds to revert to Surface Mode.
Fig. 19 - Set FO2
Fig. 20 - FO2 set for 32%
23


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Oceanic Versa Pro at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Oceanic Versa Pro in the language / languages: English as an attachment in your email.

The manual is 2,28 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Oceanic Versa Pro

Oceanic Versa Pro User Manual - German - 93 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info