554371
93
Zoom out
Zoom in
Previous page
1/96
Next page
93
OPERATIONAL PERFORMANCE (continued)
Activation:
Manual - push button (recommended)
Automatic - by immersion in water (as a backup if set ON)
H2O graphic indicates Wet Contacts are bridged (unit must be dried prior to transport or storage)
Cannot be manually activated deeper than 4 feet (1.2 m), if the Water Activation feature is set OFF.
Cannot be activated at elevations higher than 14,000 feet (4,267 m)
Shutoff:
Automatically shuts off if no dive is made within 120 minutes after initial activation. Reactivation required.
Automatically shuts off 24 hours after last dive (will reactivate if the H2O graphic is displayed).
Cannot be shut off manually.
Setting FO2:
Automatically set for 'Air' upon activation
Remains set for Air unless an FO2 numerical value is set
Nitrox set points from 21 to 50 %
If set for 21%, remains set for 21% until changed
If set for >21%, it reverts to 50% 10 minutes after the dive, if the FO2 Default is ON. If the FO2 Default is OFF, the
value will remain at the value set.
Operating Temperature:
The Veo 200/250 will operate in almost any temperature diving environment in the world, between 32 °F and 140
°F (0 and 60 °C). At extremely low temperatures, the LCD may become sluggish, but this will not affect it's
accuracy. If stored or transported in extremely low temperature areas (below freezing), you should warm the
module and its battery with body heat before diving.
ACCESSORIES (optional items available from your Authorized Oceanic Dealer):
 Lens Guard (computer module) - covers lens face, prevents scratches
 PC download package (hardware and software)
 Battery Kit - includes 1 battery, 1 battery hatch o-ring, silicone grease
SPECIFICATIONS (CONTINUED)
93


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Oceanic Veo 200 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Oceanic Veo 200 in the language / languages: English as an attachment in your email.

The manual is 2,65 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Oceanic Veo 200

Oceanic Veo 200 User Manual - German - 97 pages

Oceanic Veo 200 User Manual - French - 49 pages

Oceanic Veo 200 User Manual - Italian - 49 pages

Oceanic Veo 200 User Manual - Spanish - 49 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info