551851
31
Zoom out
Zoom in
Previous page
1/62
Next page
31
OCS OPERATING MANUAL
© 2002 Design, 2011 Doc. No. 12-5272-r01 (9/28/11)
Fig. 81 - DECO STOP ALT 2
Fig. 80 - DECO STOP ALT 1
DECO STOP MAIN, information includes (Fig. 79) -
> Full Stop icon (Stop Bar with both Arrows) solid.
> Current Depth with FT (or M) icon.
> Stop Depth with graphic FT (or M) and remaining Stop Time (hr:min).
> Graphics DECO STOP and GAS1 (or 2 or 3), one in use.
> Nx icon, if any Gas is Nitrox.
> Full TLBG with NI icon.
• A (< 2 sec) - to access ALTs.
• M (< 2 sec) - to access Gas Switching.
• S (< 2 sec) - to acknowledge alarms.
• S (2 sec) - to access Compass.
• L (press) - to activate Backlight.
Deco Stop Alt 1, information includes (Fig. 80) -
> Max Depth with FT (or M) and MAX icons.
> Graphic TAT with Total Ascent Time** (hr:min).
> Elapsed Dive Time (hr:min) with graphic EDT.
> FO2 Set Point for Gas in use with graphic FO2.
> Current PO2 value (ATA) with graphic, if Nitrox.
> Nx icon, if Nitrox.
> O2BG with O2 icon, if Nitrox.
**TAT includes Stop Times at all required Deco Stops plus vertical Ascent Time based on the max rate allowed.
• A (< 2 sec) - to access ALT 2.
• Revert to Main in 5 sec, if A not pressed.
Deco Stop Alt 2, information includes (Fig. 81) -
> Time of Day (hr:min sec), with A (or P) if 12 Hour.
> Temperature with ° icon and graphic F (or C).
• 5 sec or A (< 2 sec), revert to Main.
CONDITIONAL VIOLATION (CV)
Upon ascent above the required Deco Stop Depth, operation will enter CV during which no off gassing credit will be given; with
remaining Deco Stop Time and TAT freezing.
The Audible will sound and the LED will flash. The full TLBG and Down Arrow icon will flash (Fig. 82) until the Audible is si-
lenced, then the TLBG will be solid.
• S (< 2 sec) - to silence Audible.
> The graphic ABOVE STOP will be displayed and the Down Arrow icon will flash until descent is made to below the
required Stop Depth (within Stop Zone), then full the Stop icon (Stop Bar with both Arrows) will be on solid.
• L (press) - to activate the Backlight.
If descent below the required Deco Stop Depth is made within 5 minutes, operation will resume in Deco with off gassing credit
given (Stop Time and TAT decrease).
DELAYED VIOLATION 1 (DV1)
Once above the Deco Stop Depth for more than 5 minutes, operation will enter DV1 which is a continuation of CV**.
Again, the Audible will sound and the LED will flash. And, the full TLBG will flash (Fig. 83) until the Audible is silenced.
> Down Arrow icon continues to flash until descent to below required Stop Depth (within Stop Zone), then full Stop icon
(Stop Bar with both Arrows) will be on solid.
• L (press) - to activate the Backlight
When descent below the required Deco Stop Depth is made, operation will resume in Deco with off gassing credit given (Stop
Time and TAT decrease).
**The difference between CV and DV1 is that DV1 causes operation to enter Violation Gauge Mode 5 minutes after surfacing
from that dive.
Fig.82 - CV MAIN
(after Audible)
Fig. 83 - DV1 MAIN
(during Audible)
CV & DV1 ALTs
are similar to Deco.
Fig. 79 - DECO STOP MAIN
31


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Oceanic OCS at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Oceanic OCS in the language / languages: English as an attachment in your email.

The manual is 9,02 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Oceanic OCS

Oceanic OCS Quick start guide - English - 2 pages

Oceanic OCS Quick start guide - German - 2 pages

Oceanic OCS User Manual - German - 62 pages

Oceanic OCS Quick start guide - French - 2 pages

Oceanic OCS User Manual - French - 62 pages

Oceanic OCS Quick start guide - Italian - 2 pages

Oceanic OCS User Manual - Italian - 62 pages

Oceanic OCS Quick start guide - Spanish - 2 pages

Oceanic OCS User Manual - Spanish - 62 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info