551847
59
Zoom out
Zoom in
Previous page
1/76
Next page
59
OCi OPERATING MANUAL
© 2002 Design, 2013 Doc. No. 12-5335-r02 (9/12/13)
Fig. 157A - FREE VIOLATION
(entry into Deco, during Aud)
Fig. 157B - FREE VIOLATION
(after Aud)
Fig. 156 - FREE TLBG AL
FREE & TECH FREE DIVE ALARMS
When Alarms sound, the LED will fl ash. Also, the Backlight will come On (if Off) for 10 seconds, and a fl ashing icon or message
will be displayed as an indication that an event is occurring and as a reminder to view the display to identify the event.
When the Audible stops, the LED will extinguish and the message will clear.
If the Audible is set OFF, it will not sound and the LED will not fl ash for any cautionary situation. Any icons or messages associ-
ated with the condition will still fl ash, and the Backlight will still come On.
SURFACE CDT (COUNTDOWN TIMER) ALARM (Fig. 149)
When the CDT reaches 0:00 (min:sec), the Audible will sound 3 sets of (3) .500 second beeps during which 0:00 will fl ash on
the Surface Main then remain on solid.
SURFACE SRT (SURFACE RECOVERY TIME) ALARM (Fig. 150)
When Surface Recovery Time reaches the post dive surface interval time set (min:sec), the Audible will sound 3 sets of (3) .500
second beeps during which the graphic SRT will be displayed with the Surface Interval Time fl ashing on the Surface Main.
DIVE CDT (COUNTDOWN TIMER) ALARM (Fig. 151)
When the CDT reaches 0:00 (min:sec), the Audible will sound 3 sets of (3) .500 second beeps during which 0:00 will fl ash on
the Dive Main then remain on solid.
DIVE RTI (REPEATING TIME INTERVAL) ALARM (Fig. 152)
Each time the Elapsed Dive Time (EDT) reaches the Repeating Time Interval set, the Audible will sound (2) 1 second beeps during
which the graphic RTI will be displayed with the EDT digits fl ashing on the Dive Main, repeating after another time interval.
DIVE RDI (REPEATING DEPTH INTERVAL) ALARM (Fig. 153)
Each time Depth reaches the Interval set, the Audible will sound 3 sets of (3) .500 second beeps during which the graphic RDI
will be displayed with the Depth digits fl ashing, repeating after another depth interval. The alarm will sound even for descents
made after ascents to shallower depths are made.
RDI will not sound at the DD or DA depths set.
FREE DIVE DEPTH (DD1 to DD3) ALARMS (Fig. 154)
When an alarm Depth is reached during descent, the Audible will sound 3 sets of (3) .125 second beeps during which the gra-
phic DD1 (DD2, DD3) will be displayed with the Depth digits fl ashing on the Dive Main.
TECH FREE DIVE DEPTH (DA1 to DA6) ALARMS (Fig. 155)
When an alarm Depth is attained, during descent and/or ascent, the Audible will sound 1, 2, or 3 sets of (1 to 10) .125 second
beeps (as set) during which the graphic DA1 (DA2 to DA6) will be displayed with the Depth digits fl ashing on the Dive Main.
FREE DIVE HIGH NITROGEN ALARMS
When nitrogen increases to the caution level (4 TLBG segments), the Audible will sound 3 sets of (3) .500 second
beeps during which the TLBG segments will fl ash on the Main (Fig. 156).
If nitrogen continues to increase and reaches the Deco level (all 5 TLBG segments), the Audible will sound again
during which TLBG segments will fl ash, and NDC will be displayed as 0:00 (Fig. 157A).
When the Audible is silenced, the TLBG, NDC, and EDT are removed, replaced with the graphics VIOLATION
and UP with Up Arrows fl ashing until on the surface (Fig. 157B) for the BDSI set.
After 1 minute on the surface, the graphic VIOL alternates with FREE and dive computer operation locks into FREE
Mode for 24 hours. Access to Watch and Compass will be as usual.
Fig. 149 - SURF CDT AL
Fig. 150 - SURF SRT AL
Fig. 151 - DIVE CDT AL
Fig. 152 - DIVE RTI AL
Fig. 153 - DIVE RDI AL
Fig. 154 - FREE DD AL
Fig. 155 - TECH FREE DD AL
59


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Oceanic OCI at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Oceanic OCI in the language / languages: English as an attachment in your email.

The manual is 2,73 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Oceanic OCI

Oceanic OCI User Manual - German - 76 pages

Oceanic OCI User Manual - French - 76 pages

Oceanic OCI User Manual - Italian - 76 pages

Oceanic OCI User Manual - Spanish - 76 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info