551838
64
Zoom out
Zoom in
Previous page
1/68
Next page
64
OC1 OPERATING MANUAL
© 2002 Design, 2009 Doc. No. 12-2761-r04 (9/6/11)
CAN BE USED AS
Watch
Dive Computer (Air or Nitrox) with up to 3 Transmitters
Digital Depth Gauge/Timer with up to 3 Transmitters
Free Dive activity
Compass
DIVE COMPUTER PERFORMANCE
Buhlmann ZHL-16c based PZ+, or DSAT based, algorithm
No Deco limits closely follow PADI RDP
Decompression in agreement with Buhlmann ZHL-16c and French MN90
No Deco Deep Stops - Morroni, Bennett
Deco Deep Stops (not recommended) - Blatteau, Gerth, Gutvik
Altitude - Buhlmann, IANTD, RDP (Cross)
Altitude corrections and O2 limits based on NOAA tables
TRANSMITTERS
Battery and Pressure check
> every 2 minutes when asleep
> every 2 seconds when awake
Startup
> Pressure => 120 PSI (8 BAR)
> Battery => 2.75 volts
Shutdown
> Pressure < 50 PSI (3.5 BAR)
TMT Compatibility with Nitrox
When packaged and shipped from the factory, Oceanic TMTs are rated for use with compressed Air and Nitrox mixtures containing up to 99% O2 by volume and with 100% O2.
OPERATIONAL PERFORMANCE
Function: Accuracy:
Depth ±1% of full scale
Timers 1 second per day
Dive Mode Activation:
• Must be in Dive Computer mode, if Wet Activation is set OFF.
• Automatic by immersion in water, if Wet Activation is set ON.
• Cannot be manually activated deeper than 4 FT (1.2 M), if Water Activation is set OFF.
• Cannot operate as a DC at elevations higher than 14,000 feet (4,270 meters)
Dive Counter:
NORM/GAUG displays Dives #1 to 24, FREE displays #1 to 99 (0 if no dive made yet)
Resets to Dive #1, upon diving (after 24 hours with no dives)
Dive Log Mode:
Stores 24 most recent NORM/GAUG dives in memory for viewing
After 24 dives, adds 25th dive in memory and deletes the older dive
Altitude:
Operational from sea level to 14,000 feet (4,270 meters) elevation
Measures ambient pressure every 30 minutes in Watch Mode, when Dive Computer Mode is accessed, and every 15 minutes while in NORM/GAUG/FREE Surface Modes.
Does not measure ambient pressure when Wet.
Compensates for Altitudes above sea level beginning at 3,001 feet (916 meters) elevation and every 1,000 feet (305 meters) higher.
Power:
• Watch Battery (1) 3 vdc, CR2450, Lithium battery (Panasonic or equivalent)
• Transmitter Battery (1) 3 vdc, CR2, .75 Ahr, Lithium battery (Duracell model DL-CR2 or equivalent)
• Shelf life Up to 7 years (when shipped from factory in Deep Sleep mode)
• Replacement User replaceable (annual recommended)
• Use Life (OC1) 1 year or 300 dive hours if (2) 1 hour dives per dive day
• Use Life (Transmitter) 300 dive hours if (2) 1 hour dives per dive day
Battery Icon (OC1 only):
Warning >> icon on solid when <= 2.75 volts, Battery change recommended
Alarm >> icon on flashing when <= 2.50 volts, change the Battery, will not function as a DC
Operating Temperature:
Out of the water >> between 20 °F and 140 °F (-6 and 60 °C).
In storage case provided >> between 14 °F and 158 °F (-8 and 70 °C).
In the water >> between 28 °F and 95 °F (-2 and 35 °C).
BAR GRAPHS
TLBG segments O2BG segments
• No Deco Normal zone 3 • Normal zone 3
• No Deco Caution zone 1 • Caution zone 1
• Decompression zone 1 • Danger zone 1
VARI 60 FT (18 M) & Shallower Deeper than 60 FT (18 M)
segments FPM MPM segments FPM MPM
0 0 - 10 0 - 3 0 0 - 20 0 - 6
Normal Zone 1 11 - 25 3.5 - 7.5 1 21 - 50 6.5 - 15
Caution Zone 2 26 - 30 8 - 9 2 51 - 60 15.5 - 18
Too Fast Zone (flashing) 3 (all) > 30 > 9 3 (all) > 60 > 18
SPECIFICATIONS
64


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Oceanic OC1 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Oceanic OC1 in the language / languages: English as an attachment in your email.

The manual is 8,03 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Oceanic OC1

Oceanic OC1 User Manual - English - 180 pages

Oceanic OC1 Additional guide - German - 2 pages

Oceanic OC1 Quick start guide - German - 2 pages

Oceanic OC1 User Manual - German - 68 pages

Oceanic OC1 Additional guide - French - 2 pages

Oceanic OC1 Quick start guide - French - 2 pages

Oceanic OC1 User Manual - French - 68 pages

Oceanic OC1 Additional guide - Italian - 2 pages

Oceanic OC1 User Manual - Italian - 68 pages

Oceanic OC1 User Manual - Turkish - 180 pages

Oceanic OC1 User Manual - Spanish - 68 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info