• Dive Computer (Air or Nitrox) with up to 3 Transmitters
• Digital Depth Gauge/Timer with up to 3 Transmitters
• Free Dive activity
• Compass
DIVE COMPUTER PERFORMANCE
• Buhlmann ZHL-16c based PZ+, or DSAT based, algorithm
• No Deco limits closely follow PADI RDP
• Decompression in agreement with Buhlmann ZHL-16c and French MN90
• No Deco Deep Stops - Morroni, Bennett
• Deco Deep Stops (not recommended) - Blatteau, Gerth, Gutvik
• Altitude - Buhlmann, IANTD, RDP (Cross)
• Altitude corrections and O2 limits based on NOAA tables
TRANSMITTERS
• Battery and Pressure check
> every 2 minutes when asleep
> every 2 seconds when awake
• Startup
> Pressure => 120 PSI (8 BAR)
> Battery => 2.75 volts
• Shutdown
> Pressure < 50 PSI (3.5 BAR)
TMT Compatibility with Nitrox
When packaged and shipped from the factory, Oceanic TMTs are rated for use with compressed Air and Nitrox mixtures containing up to 99% O2 by volume and with 100% O2.
OPERATIONAL PERFORMANCE
Function:Accuracy:
• Depth ±1% of full scale
• Timers 1 second per day
Dive Mode Activation:
• Must be in Dive Computer mode, if Wet Activation is set OFF.
• Automatic by immersion in water, if Wet Activation is set ON.
• Cannot be manually activated deeper than 4 FT (1.2 M), if Water Activation is set OFF.
• Cannot operate as a DC at elevations higher than 14,000 feet (4,270 meters)
Dive Counter:
• NORM/GAUG displays Dives #1 to 24, FREE displays #1 to 99 (0 if no dive made yet)
• Resets to Dive #1, upon diving (after 24 hours with no dives)
Dive Log Mode:
• Stores 24 most recent NORM/GAUG dives in memory for viewing
• After 24 dives, adds 25th dive in memory and deletes the older dive
Altitude:
• Operational from sea level to 14,000 feet (4,270 meters) elevation
• Measures ambient pressure every 30 minutes in Watch Mode, when Dive Computer Mode is accessed, and every 15 minutes while in NORM/GAUG/FREE Surface Modes.
• Does not measure ambient pressure when Wet.
• Compensates for Altitudes above sea level beginning at 3,001 feet (916 meters) elevation and every 1,000 feet (305 meters) higher.
Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.
Product:
Forumrules
To achieve meaningful questions, we apply the following rules:
First, read the manual;
Check if your question has been asked previously;
Try to ask your question as clearly as possible;
Did you already try to solve the problem? Please mention this;
Is your problem solved by a visitor then let him/her know in this forum;
To give a response to a question or answer, do not use this form but click on the button 'reply to this question';
Your question will be posted here and emailed to our subscribers. Therefore, avoid filling in personal details.
Register
Register getting emails for Oceanic OC1 at:
new questions and answers
new manuals
You will receive an email to register for one or both of the options.
Get your user manual by e-mail
Enter your email address to receive the manual of Oceanic OC1 in the language / languages: English as an attachment in your email.
The manual is 8,03 mb in size.
You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.
If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.
The email address you have provided is not correct.
Please check the email address and correct it.
Your question is posted on this page
Would you like to receive an email when new answers and questions are posted? Please enter your email address.