OC1 OPERATING MANUAL
© 2002 Design, 2009 Doc. No. 12-2761-r04 (9/6/11)
OVERVIEW
> S (2 sec) - to access** from Watch or Surface Main
> S ( 2 sec) - to revert to Watch or Surface Main
> 60 sec (no button action) - revert to Watch or Surface Main
> Only active while OP Main is displayed
> OP (operating) Mode - select North or Reference on surface
> OP Mode selected - remains until changed.
> Reference Auto Home - can select on surface or underwater, only while in Reference OP Mode
> Remains in Auto Home until 10 minutes after surfacing, then reverts to Reference Mode with Heading selected.
> Surface - can access OP Main, select Ref Auto Home if in Reference, and access Menu.
> Underwater - can only access OP Main, and select Ref Auto Home if in Reference.
> Numeric values are always 3 digits (000 to 360°)
Upon accessing the Compass (Fig. 144), the OP (operating) Mode last selected will be displayed (North, Reference, or Ref
Auto Home).
During dives, current Depth will also be displayed (Fig. 145).
While on the surface, press M (< 2 sec) to access the Menu to change the OP Mode, Calibrate, or set Declination.
COMPASS MENU
M (< 2 sec) - to access Menu, while viewing Compass OP Main
A (< 2 sec) - to step down (forward) through selections
M (< 2 sec) - to step up (back) through selections
S (< 2 sec) - to access selection indicated by Arrow icon ( > )
M (2 sec) any time - to revert to OP Main
1 min (no button action) - will revert to Watch or DC Main
CALIBRATION
Local magnetic fields can effect display of actual location when reading a digital compass. It may be advantageous to Cali-
brate the Compass before its first use after purchase, use in new regions, or if inaccuracies are experienced. Calibration will be
required when the battery is changed.
CAL Access/Start**, information includes (Fig. 146) -
> Graphics CAL and ROTATE
> 360 with ° icon
• S (< 2 sec) - to activate (start) Calibration
• Slowly and steadily rotate the OC1 360° in either direction while maintaining it in a flat level position (keeping it level is
critical for acurracy), CAL progress will be displayed.
** The CAL ROTATE screen will also be accessed after the Battery is changed and Data is either saved or cleared.
CAL Progress**, information includes (Fig. 147) -
> Graphic CAL
> dotted circle, increasing from 0 to 360° as it is rotated
**Rotation should take about 30 seconds. If not fully rotated in 60 seconds, operation will revert to the Menu.
CAL Complete, information includes (Fig. 148A/B) -
> Graphic CAL
> Graphic READY or AGAIN, flashing for 3 seconds
* READY, means it passed, in which case Calibration is complete and operation reverts to the OP Main.
* AGAIN, means it failed**, in which case the CAL ROTATE screen will be displayed. Press S (< 2 sec) to repeat the rotation.
**If Calibration fails after 3 attempts, operation will revert to the Watch or Surface Main from which it was accessed. If you
then continue operation, the previous successful Calibration will remain in effect.
Fig. 144 - NORTH OP MODE
(surface)
Fig. 145 - REF OP MODE
(during dive)







Fig. 146 - START CAL
Fig. 147 - CAL PROGRESS
Fig. 148A - CAL FAILED
Fig. 148B - CAL PASSED
54


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Oceanic OC1 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Oceanic OC1 in the language / languages: English as an attachment in your email.

The manual is 8,03 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Oceanic OC1

Oceanic OC1 User Manual - English - 180 pages

Oceanic OC1 Additional guide - German - 2 pages

Oceanic OC1 Quick start guide - German - 2 pages

Oceanic OC1 User Manual - German - 68 pages

Oceanic OC1 Additional guide - French - 2 pages

Oceanic OC1 Quick start guide - French - 2 pages

Oceanic OC1 User Manual - French - 68 pages

Oceanic OC1 Additional guide - Italian - 2 pages

Oceanic OC1 User Manual - Italian - 68 pages

Oceanic OC1 User Manual - Turkish - 180 pages

Oceanic OC1 User Manual - Spanish - 68 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info