© 2002 Design, 2009 Doc. No. 12-2761-r04 (9/6/11)
Deep Stop Alt 2, information includes (Fig. 82) -
> Time of Day (hr:min sec), with A (or P) if 12 Hour
> Temperature with ° icon and graphic F (or C)
• 5 sec or A (< 2 sec), revert to Main
SAFETY STOP MAIN, information includes (Fig. 83) -
> Current Depth with FT (or M) icon
> Stop Depth with graphic FT (or M) and remaining countdown Time (min:sec)
> ATR (min) when 60 minutes or less with graphic ATR and Time (clock) icon, blank if no TMT
> Graphic GAS1 (or 2 or 3), one in use
> Pressure with PSI (or BAR) and Link icons, if Rcvr and TMT are active, flashing when Link is lost
> Nx icon, if any Gas is Nitrox
> TLBG with NI icon
• A (< 2 sec) to access ALTs
• M (2 sec) to access Gas Switching
• S (< 2 sec) to acknowledge alarms
• S (2 sec) to access Compass
• L (closure) to activate Backlight
Safety Stop Alt 1, information includes (Fig. 84) -
> Max Depth with MAX and FT (or M) icon
> DTR (hr:min) with graphic NDC (or OTR if less)
> Graphic EDT with Elapsed Dive Time (hr:min)
> Graphic FO2 with Set Point for Gas in use
> Graphic PO2 with current value (ATA), if Nitrox
> Nx icon, if Nitrox
> O2BG with O2 icon, if Nitrox
• A (< 2 sec) to access ALT 2
• Revert to Main in 5 sec, if A not pressed
Safety Stop Alt 2, information includes (Fig. 85) -
> Time of Day (hr:min sec), with A (or P) if 12 Hour
> Temperature with ° icon and graphic F (or C)
• 5 sec or A (< 2 sec), revert to Main
DECOMPRESSION MODE
Decompression mode activates when theoretical No Decompression time and depth limits are exceeded.
Upon Entry into Deco, the Audible will sound and the red LED will flash. The full TLBG and Up Arrow icon will flash (Fig. 86),
until the Audible is silenced.
• S (< 2 sec) to silence Audible
> Up Arrow icon flashes if 10 FT (3 M) deeper than the required Stop Depth.
> Once within 10 FT (3 M) of and below the required Stop Depth (Stop Zone), the full Stop icon (both Arrows with Stop Bar)
will be displayed solid.
• L (closure) to activate the Backlight
Managing Deco Stops
To fulfill your decompression obligation, you should make a safe controlled Ascent to a depth slightly deeper than, or equal to,
the required Stop Depth indicated and decompress for the Stop Time indicated.
The amount of decompression credit time that you receive is dependent on Depth, with slightly less credit given the deeper you
are below the Stop Depth indicated.
You should stay slightly deeper than the Required Stop Depth indicated until the next shallower Stop Depth appears. Then, you
can slowly ascend to, but not shallower than that indicated Ceiling Stop Depth.
DECO STOP MAIN, information includes (Fig. 87) -
> Full Stop icon (Stop Bar with both Arrows) solid
> Current Depth with FT (or M) icon
> Stop Depth with graphic FT (or M) and remaining Stop Time (hr:min)
> ATR (min) when 60 minutes or less with graphic ATR and Time (clock) icon, blank if no TMT
> Graphic GAS1 (or 2 or 3), one in use
> Pressure with PSI (or BAR) and Link icons, if Rcvr and TMT are active, flashing when Link is lost
> Nx icon, if any Gas is Nitrox
> Full TLBG with NI icon
Fig. 82 - DEEP STOP ALT 2
Fig. 83 - SAFETY STOP
MAIN
Fig. 84 - SAFETY STOP
ALT 1
Fig. 85 - SAFETY STOP
ALT 2
Fig. 86 - DECO ENTRY
Fig. 87 - DECO STOP MAIN
34


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Oceanic OC1 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Oceanic OC1 in the language / languages: English as an attachment in your email.

The manual is 8,03 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Oceanic OC1

Oceanic OC1 User Manual - English - 180 pages

Oceanic OC1 Additional guide - German - 2 pages

Oceanic OC1 Quick start guide - German - 2 pages

Oceanic OC1 User Manual - German - 68 pages

Oceanic OC1 Additional guide - French - 2 pages

Oceanic OC1 Quick start guide - French - 2 pages

Oceanic OC1 User Manual - French - 68 pages

Oceanic OC1 Additional guide - Italian - 2 pages

Oceanic OC1 User Manual - Italian - 68 pages

Oceanic OC1 User Manual - Turkish - 180 pages

Oceanic OC1 User Manual - Spanish - 68 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info