SPECIFICATIONS (cont'd)
GRAPHIC DIVER INTERFACE
Tissue Loading Bar Graph (TLBG)
segments
No Decompression zone (green) 12
Caution zone (yellow) 3
Decompression zone (red) 1
Oxygen Accumulation (O2) Bar Graph
segments
Normal zone (green) 12
Caution zone (yellow) 3
Danger zone (red) 1
Variable Ascent Rate Indicator (VARI)
segments feet/min. meters/min.
Too Fast zone (red - flashing) 5 61+ 18.5 +
Caution zone (yellow) 4 51 - 60 15.5 - 18
3 41 - 50 12.5 - 15
2 31 - 40 9.5 - 12
Normal zone (green) 1 21 - 30 6.5 - 9
0 0 - 20 0 - 6
Special Displays: Occurrence
Diagnostic Display Activation
Out of Range 330+ feet (99.5+ meters)
Gauge Mode Countdown Timer 12 - 24 hours after violation
External Access (EA) If control button is held for 8 sec
during Surface or PDPS mode.
OPERATIONAL PERFORMANCE
Function: Accuracy:
Depth ± 1% of full scale
Timers 1 second per day
Dive Counter:
Displays Dives #1 - #9 then recycles to #1 (and continues #1 - #9)
Resets to Dive #1, upon diving (after a 12 hour surface time)
Cycles to next Dive # at 5 feet (1.5 meters) depth after a 10 minute
surface interval
Dive Log Mode:
Stores latest (most recent) 12 dives in memory for viewing
After 12 dives, adds latest dive to memory, deletes oldest dive
Each dive displays a Nitrogen Log & an Oxygen Log screen
Altitude:
• Altitude range 0 - 14,000 feet (4,267 m) above sea level
• Modes Full computer functions up to 14,000 feet (4,267 m)
• Activation not possible when higher than 14,000 feet (4,267 m).
• Recalibration of depth readings from 'feet of sea water' to 'feet of fresh
water' when higher than 2,000 feet (610 m) elevation.
Power:
• Batteries Two 3 volt lithium cells, CR2032 or equivalent
• Life expectancy 50 - 24 hour periods of activation (approximate)
(variable number of dives)
• Shelf life 2 to 5 yrs (see battery manufacturer's specs)
• Low Battery condition Replace both prior to diving
R3
96


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Oceanic Data Plus at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Oceanic Data Plus in the language / languages: English as an attachment in your email.

The manual is 1,34 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info