550349
53
Zoom out
Zoom in
Previous page
1/56
Next page
53
ATOM 3.0 OPERATING MANUAL
© 2002 Design, 2011 Doc. No. 12-5216-r02 (9/6/11)
NUMERIC DISPLAYS: Range: Resolution:
Main Time of Day 00:00_00 to 23:59_59 hr:min_sec 1 second
Dual Time of Day 00:00 to 23:59 hr:min 1 minute
Dual Time Differential - 23 hr to 0 to + 23 hr 1 hour
Watch Countdown Timer 23:59 to 0:00 hr:min 1 minute
Watch Chrono Lap # 1 to 9 1 (lap)
Watch Chrono Lap Time 0:00 to 1:59:59_99 .01 second
(hr:min:sec_.01 sec)
PCI Countdown Timer 1:59 to 0:00 min:sec 1 second
Altitude Level Sea, EL-2 to EL-7 1 (level)
Time to Fly 23:50 to 0:00 hr:min 1 minute
(starting 10 min after the dive)
Time to Desaturate 23:50 to 0:00 hr:min 1 minute
(starting 10 min after the dive)
Temperature 0 to 99°F (-18 to 60°C) 1°F (C)
Depth (display) 0 to 330 FT (100 M) 1 FT (0.1/1 M )
Max Operating Depth 330 FT (100 M)
Tank Pressure 0 to 5000 PSI (345 BAR) 5 PSI (1 BAR)
NORM/GAUG SI Time 0:00 to 23:59 hr:min 1 minute
NORM/GAUG Dive Number 0 to 24 1 (dive)
NORM EDT 00 to 199 min 1 minute
GAUG EDT (with Run Time) 00 to 99 min 1 minute
GAUG EDT (without Run Time) 00 to 999 min 1 minute
NORM DTR (NDC, OTR) 0 to 199 min 1 minute
NORM/GAUG ATR 0 to 199 min 1 minute
FO2 (1, 2, 3) Set Points Air, 21 to 100 % 1 %
PO2 Value 0.00 to 5.00 ATA .01 ATA
O2 Saturation 0 to 100 % 1 %
No Deco Deep Stop Time 2:00 to 0:00 min:sec 1 second
No Deco Safety Stop Time 5:00 to 0:00 min:sec 1 second
Safety Stop Run Timer 0:00 to 9:59 min:sec 1 second
GAUG Dive Run Timer 0:00 to 199:59 min:sec 1 second
Deco Stop Time 1 to 99 min 1 minute
Total Ascent Time 1 to 199 min 1 minute
Violation Countdown Timer 23:50 to 0:00 hr:min 1 minute
FREE SI Time (< 1 hr) 0:00 to 59:59 min:sec 1 second
FREE SI Time (=> 1 hr) 1:00 to 23:59 hr:min 1 minute
FREE Dive Number 0 to 99 1
FREE Countdown Timer 59:59 to 0:00 min:sec 1 second
FREE EDT (< 1 min) 0 to 59 sec 1 second
FREE EDT (=> 1 min, no NDC) 1_00 to 59_59 min_sec 1 second
FREE EDT (=> 1 min, with NDC) 1 to 59 min 1 minute
SPECIFICATIONS (CONTINUED)
WARNING: If your ATOM 3.0 stops working for any reason while operating as a Dive Computer, it is important
that you have anticipated this possibility and are prepared for it. This is an important reason for not pushing the
no decompression and oxygen exposure limits, and a critical reason to avoid entering decompression.
If you dive in situations where your trip would be ruined or your safety would be jeopardized by losing the use of
your ATOM 3.0, a backup instrument system is highly recommended.
FCC ID: MH8A
FCC COMPLIANCE:
This equipment complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: 1.) this equipment may not cause harmful interference, and 2.) this equipment must accept any interference received,
including interference that may cause undesired operation.
FCC INTERFERENCE STATEMENT:
This equipment has been tested and found to comply with the limits for an Intentional Radiator, a Class B Digital Device, pursuant to Part 15 of FCC Rules, Title 47 of the Code of Federal Regulations. These rules are designed to
provide reasonable protection against harmful interference in a commercial or residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the
instructions, may cause harmful interference to radio communications.
There is no guarantee that interference will not occur in a particular installation. If this equipment does cause interference to radio or television reception, which can be determined by turning the equipment off and on, the user is
encouraged to try to correct the interference by one or more of the following measures:
• Reorient or relocate the receiving antenna.
• Increase the separation between the equipment and receiver.
• Connect the equipment to an outlet on a circuit different from that to which the receiver is connected.
• Consult the dealer or an experienced radio/TV technician.
Warning: Changes or modifications to this unit not expressly approved by Oceanic/2002 Design could void the user's authority to operate the equipment.
53


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Oceanic Atom 3.0 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Oceanic Atom 3.0 in the language / languages: English as an attachment in your email.

The manual is 12,62 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Oceanic Atom 3.0

Oceanic Atom 3.0 Quick start guide - English - 2 pages

Oceanic Atom 3.0 User Manual - German - 56 pages

Oceanic Atom 3.0 Quick start guide - French - 2 pages

Oceanic Atom 3.0 User Manual - French - 56 pages

Oceanic Atom 3.0 Quick start guide - Italian - 2 pages

Oceanic Atom 3.0 User Manual - Italian - 56 pages

Oceanic Atom 3.0 User Manual - Spanish - 56 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info