ATOM 3.0 OPERATING MANUAL
© 2002 Design, 2011 Doc. No. 12-5216-r02 (9/6/11)
TIME TO FLY (NORM/GAUG)
Time to Fly is a countdown timer that begins counting down from 23:50 to 0:00 (hr:min) 10 minutes after surfacing from a dive
(NORM, GAUG, or FREE).
FLY, information includes (Fig. 37):
> Time to Fly countdown (hr:min), - : - - if no dive yet, 0:00 if time has elapsed.
> Graphic FLY.
• A (< 2 sec) - to step forward to DSAT if NORM, or LOG if GAUG.
• M (< 2 sec) - to step back to ALT 3 if Nitrox, or ALT 2 if Air or GAUG.
DSAT TIME (NORM only)
Time to Desaturate (Dsat Time) is also a countdown timer. It is calculated time for tissue desaturation at sea level.
Beginning 10 minutes after surfacing from a NORM or FREE dive, it counts down from a maximum of 23:50 to 0:00 (hr:min).
Dsat requiring more than 24 hours will display 24HR until it decreases to 23:59.
After a FREE dive, access to the DSAT screen can be gained by first accessing the NORM Mode.
After a violation dive, 3 dashes ( - - - ) will be displayed in place of countdown time.
> When other screens are accessed, the DSAT time continues to countdown in the background.
> In the event that time to desaturate still remains at the end of 24 hours, any remaining time will be cleared.
We do not go beyond 24 hours since there is not a realistic set of repetitive dive profiles on SCUBA for which the 480 minute tissue exceeds 8 FSW, which clears
at 24 hours. All other tissues with a half time of 160 minutes or less will have desaturated in less than 12 hours.
DSAT, information includes (Fig. 38):
> Time to Desaturate (hr:min), - : - - if no dive yet, 0:00 if no time remaining.
> Graphic DSAT.
• A (< 2 sec) - to step forward to PLAN.
• M (< 2 sec) - to step back to FLY.
PLAN MODE (NORM only)
Dive time calculations in Plan Mode are based on -
> the algorithm selected (DSAT or PZ+).
> the FO2 value set for Gas 1, the default used for Plan.
> the setting for the Conservative Factor (Off or On*).
> any residual nitrogen remaining, or oxygen accumulation, from previous dives (NORM or FREE)
*When the Conservative Factor is set On, Dive times are reduced to the values of the next higher 3000 foot (915 meter) Altitude. Refer to tables in back.
Plan Lead-in, information includes (Fig. 39A, B):
> (PZ+) icon if selected, no icon if DSAT.
> Graphic PLAN.
> CF icon, if set On.
> Graphic AIR, or PO2 alarm value set (ATA) with PO2 and NX icons if Nitrox.
> Gas 1 FO2 Set Point, 21 to 100 (%), with FO2 icon, if Nitrox.
> Gas 1 (tank) icon, default for Plan.
• A (< 2 sec) - to step forward to Log.
• M (< 2 sec) - to step back to DSAT.
• S (< 2 sec) - to access PDPS.
PDPS (Pre Dive Planning Sequence)
The PDPS displays Depths and allowable Dive Times (up to 999 minutes), NDLs (No Deco limits) if nitrogen loading is in control
or OTLs (O2 limits) if oxygen accumulation is in control.
PDPS screens will display Depths from 30 to 190 FT (9 to 57 M) with Plan times* based upon the previous dive profiles in a
series of repetitive dives and taking into account descent and ascent rates of 60 FPM (18 MPM).
*If less then 1 minute time is available, dashes will be displayed for time, and Depth values will flash.
PDPS, information includes (Fig. 40A, B):
> Plan Depth value with FT (or M) icon.
> Dive Time allowed with NDC (or O2) and min icons.
> Graphic AIR, or Gas 1 FO2 Nitrox Set Point (21 to 100) with FO2 icon.
> Gas 1 (tank) icon, default for Plan.
> NX, (PZ+), CF icons - if they apply.
Fig. 37 - TIME TO FLY
(beginning 10 min after dives)
Fig. 38 - TIME TO DSAT
Fig. 39A - PLAN LEAD-IN
(FO2 Gas 1 set for Air)
Fig. 39B - PLAN LEAD-IN
(FO2 Gas 1 set for Nitrox)
Fig. 40B - PDPS
(FO2 Gas 1 set for Nitrox)
Fig. 40A - PDPS
(FO2 Gas 1 set for Air)
17


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Oceanic Atom 3.0 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Oceanic Atom 3.0 in the language / languages: English as an attachment in your email.

The manual is 12,62 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Oceanic Atom 3.0

Oceanic Atom 3.0 Quick start guide - English - 2 pages

Oceanic Atom 3.0 User Manual - German - 56 pages

Oceanic Atom 3.0 Quick start guide - French - 2 pages

Oceanic Atom 3.0 User Manual - French - 56 pages

Oceanic Atom 3.0 Quick start guide - Italian - 2 pages

Oceanic Atom 3.0 User Manual - Italian - 56 pages

Oceanic Atom 3.0 User Manual - Spanish - 56 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info