554354
168
Zoom out
Zoom in
Previous page
1/180
Next page
CAN BE USED AS
Watch
Dive Computer (Air or Nitrox)
Digital Depth Gauge/Timer
Free Dive activity
With or without up to 3 Transmitters
NO DECOMPRESSION MODEL
Basis:
Modified Haldanean Algorithm
12 tissue compartments
Data Base:
Diving Science and Technology (DSAT) - Rogers/
Powell
Dive Computer Performance:
Tissue compartment halftimes (mins.) Spencers M
values
5, 10, 20, 40, 80, 120, 160, 200, 240, 320, 400, 480
Reciprocal subsurface elimination
60 minute surface credit control for compartments
faster than 60 minutes
Tissue compartments tracked up to 24 hours after
last dive
Decompression Capabilities (stop ceilings):
10, 20, 30, 40, 50, and 60 FT
(3, 6, 9, 12, 15, and 18M)
Altitude Algorithm and Oxygen Exposure Limits:
Based on NOAA tables
TRANSMITTERS
Battery and Pressure check
> every 2 minutes when asleep
> every 2 seconds when awake
Startup
> Pressure equal or greater than 120 PSI (8 BAR)
> Battery equal or greater than 2.75 volts
Shutdown
> Pressure less than 50 PSI (3.5 BAR)
WATCH MODES
Main Time (home)
> Set Time/Date
 Alternate Time (remote location)
> Set Alternate Time (hour differential)
Countdown Timer
> Set/Start/Stop
Chronograph (Stop Watch/Lap Timer)
> Start/Stop/Lap Recall/Reset
Daily Alarm (Watch Mode)
> Set Time, On/Off
DIVE COMPUTER SURFACE SEQUENCE/MODES
NORM/GAUG/FREE Surface Mode
Plan (30 to 190 FT/9 to 57 M) - NORM only
Time to Fly Countdown - NORM/GAUG
Time to Desaturation Countdown - NORM only
Dive Log - NORM/GAUG
History - NORM/GAUG
Oxygen Data (after Nitrox dives)
Battery/Tank Pressure Status - NORM/GAUG
Set FO2, Alarms, Utilities - NORM/GAUG
168


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Oceanic Atom 2.0 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Oceanic Atom 2.0 in the language / languages: English as an attachment in your email.

The manual is 7,08 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Oceanic Atom 2.0

Oceanic Atom 2.0 Quick start guide - German - 2 pages

Oceanic Atom 2.0 User Manual - Dutch - 176 pages

Oceanic Atom 2.0 User Manual - French - 176 pages

Oceanic Atom 2.0 Quick start guide - Italian - 3 pages

Oceanic Atom 2.0 User Manual - Italian - 186 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info