To decrease the power level press key
2
.
Three green LEDs
5
show positions one to three.
The red LED
6
shows the Power position. The Power
position is only used if there are strong odours, or a lot
of smoke or vapour. Its use must be kept to a minimum
because of the large extraction of air in this position.
The Power position automatically goes back to speed
three after 6 minutes.
The motor has a thermal switch that switches the motor
off with overheating. After cooling the motor will switch
on again.
Determining the cause of overheating is re-
quired. This can be caused for example by a
pan fi re, theimpeller motor being blocked or
an object getting in the exhaust opening and
causing it to bepartly or fully blocked.
Auto-Stop
To avoid the extractor hood from staying on, the motor is
automatically switched off after 3 hours (only if in 3 hours
operation has not been changed). The extractor hood
lighting stays on.
2.3 Lighting
Turning the lighting on and off
To turn the lighting on or off press
4
.
The light works independent of the motor.
The LED lighting has a soft on/soft off mode, which means
that the lighting will evenly go on and off. When switching
on the lighting, this will always light up with full power and
it can also be used when the fan is off.
Dimming LED lighting
When the LED lighting has been switched on, it can be
dimmed by keeping key
4
pressed.
Change in colour temperature with LED-lighting
You can change the colour temperature of the LED-lighting
form 2.700 K (warm white) into 4.000 K (neutral white). The
description for changing this can be found in section 3.4.
2.4 Programming recirculation (optional)
If recirculation is selected programming must
takeplace once.
This programming function activates the replacement
indicator of the monobloc recirculation fi lter and the delay
time is changed.
Activating programming
The motor must be switched off
Press the
2
and the
3
keys at the same time for 3
seconds until the red LED fl ashes 5 times.
The following functions then operate:
Replacement indicator of the monobloc fi lter is activated.
After a set time a red indicator light on theappliance
shows that the monobloc fi lter must be replaced.
The delay time is set to 30 minutes (instead of the default
10 minutes).
Use the delay time of 30 minutes so the
cookingodours can be properly removed in
the monobloc fi lter.
Read paragraph 3.3 for more information about replacement
of the monobloc recirculation fi lter.
Deactivating programming
The motor must be switched off
Press
2
and
3
at the same time for 3 seconds until
the 3rd green LED fl ashes 3 times.
The delay time is again set to 10 minutes (instead of 30 min-
utes) and cleaning indicator for recirculation is switched off.
36


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Novy 826 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Novy 826 in the language / languages: English, German, Dutch, French as an attachment in your email.

The manual is 1,13 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Novy 826

Novy 826 Installation Guide - English, German, Dutch, French - 26 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info