517648
22
Zoom out
Zoom in
Previous page
1/36
Next page
EN 22
• Click the cover plate (A) loose with a light de-
scending push.
• When you want to replace the cover plate (A)
don’t forget to replace the adjusting clips over
the plugs and to tighten the screws.
Remove the grease filter
• Remove the grease filter to get acces to the
screws witch hold the glass panels (see main-
tenance).
Remove the glass panels
• Loosen First the screws before you remove the
glass panels (A).
• Tip the glass panel (A) over the filterholder (B)
• Watch out: Support the glass panel with the in-
tegrated command, so the cable (C) that lies
underneath doens’t get damaged.
Cleaning the glass panels and cover plate
• Don’t put the panels and the cover plate in the
dishwasher and don’t plunge them in water
completely.
• Keep the control dry while cleaning the glass
panel.
Replacement of the lights
• Turn the fluorescent lights with a quarter turn to
take it out of its support.
• Place the new light in its support and turn again
with a quarter turn until you hear a clicking
sound.
Model 7505-7507
Novy reference 898.025
Reference lamp T8 F25W/33”/840
Programming the saturation indication
(Attention! Programming can only take place
when the hood is switched off)
• push + and - at the same time, during 5 min..
(the red led will blink 5 times)
• delay time is programmed for 30 minutes
(instead of 10 min.).
• the saturation indication is programmed (200
working hours).
After 200 working hours the red LED will blink
(time to reactivate the monoblock filter)
Reprogramming of the saturation indication.
(Attention! Programming can only take place
when the hood is switched off)
• push + and - at the same time, during 5 min..
(the red led will blink 5 times) or automatically
after pressing 10 times the on/off button 0/I
Deactivating the saturation indication (Atten-
tion! Programming can only take place when
the hood is switched off)
• push + and - at the same time, during 5 min..
(the 3rd green LED will blink 5 times)
Maintenance of the hood
Please allow the lights to cool down sufficiently
before cleaning the hood. Use a soft, wet cloth
and a mild detergent to clean the hood.
Never use aggressive, abrasive detergents or
sponges. Bleach will damage stainless steel.
The stainless steel surfaces can be treated with
Novy Inoxcleaner (906.060) after cleaning.
Replacement of the fluorescent lighting
Remove first the electrical plug from the electrical
point.
Remove the cover plate
• Open the cover plate (A) by pulling it down.
• Remove the cover plate (A) by converting the
adjusting clips (B). Don’t loosen the screws
completely!
22


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Novy 7505 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Novy 7505 in the language / languages: English, German, Dutch, French as an attachment in your email.

The manual is 0,49 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info