Condensation may arise as a result of temperature
differences if the extraction duct passes through cool
rooms. Ensure that the extraction duct is insulated.
In case of an exhaust pipe through the outside wall
passing a cavity wall, make sure that the exhaust duct
fully bridges the cavity and slightly declines to the
outside.
In case of an exhaust pipe through the wall, use a
wall vent.
In case of an exhaust pipe through the roof, use a double-
walled roof passage with adequate outlet capacity.
When connecting to a short extraction duct, it may
be desirable to install a non-return valve in the duct
in order to prevent backdraught from wind.
Make sur
e that sufficient air is supplied. Fresh air can
be supplied by slightly opening a window or an outside
door or by installing an inlet grate.
The appliance may not be connected to a flue or chim-
ney that is currently in use, or that serves as ventilation
for rooms with hearths.
Air supply
However large the kitchen or the room with open kitchen
is, only so much air can be extracted from the room as
is supplied. Too little air supply could result in a yield
loss of 50% and more.
If the extraction is used at the same time as a combus-
tion system (for example heaters fired by gas, oil, wood
or coal, hot water boilers using gas, gas hobs and gas
ovens), combustion gases may be sucked back in and
lead to poisoning.
A combustion system uses air from the room as com-
bustion air. Combustion gases arise as a result, which
are removed to the outside by an extraction system.
The appliance sucks in air from the kitchen and adjacent
rooms. Negative pressure occurs if the air supply is in-
adequate. The toxic gases are then sucked back from
the chimney or extraction duct into the room.
With simultaneous use of the appliance and combustion
appliances in the same room, the negative pressure may
not exceed 4 Pa (=0.04 mBar). Negative pressure can be
prevented by allowing sufficient air into the room through
openings that cannot be closed (for example through
windows or doors, in combination with a ventilation
cabinet in the wall).
Have an expert assess the overall ventilation system in
your home for a proposal on suitable measures in the
area of air supply.
When using the appliance with an internal or external
motor (unit) with air extraction to the outside, there must
be adequate air supply in the room where the appliance
has been installed / is positioned, so that fresh air can
flow in. Fresh air can be provided by tilting a window,
opening a door or installing an inlet grille.
With an appliance with recirculation, there must be a
minimum of ventilation in the room where the appliance
has been installed / is positioned. Ventilation can be
provided by the overall ventilation in the home or by
tilting a window or opening a door.
Certain appliances are fitted with a connection for a
window contact switch (see the technical specifications
for your appliance). If the appliance is to operate at the
same time as a heating appliance that needs air from
the room, and if the required supply can only take place
through a single open window, there is the option of
connecting the appliance to a window contact switch
(not included). This ensures that the appliance operates
only when the window is open. If the window is closed,
the fan cannot be switched on.
Contact your technician for the correct accessories for
your appliance.
Installation instructions for the outlet
The appliance may only be connected with the power
plug to a socket with an earth (230 V – 50 Hz).
Safety is only assured when the appliance is connected
to an earth cable in accordance with the instructions
laid down.
The appliance must be able to be disconnected from
the power at any desired point.
Position the socket in such a way that the power plug
of the appliance can be inserted easily.
Do not use an extension cable for the connection to
the electrical mains.
Electric shock: never switch on a faulty appliance, this
could cause an electric shock. Take the power plug out
of the socket, or switch off at the distribution cabinet.
Contact the Novy service department.
Repairs and replacing faulty or damaged wiring must
only be carried out by technicians who have undergone
instruction by Novy.
Moisture that has got into the appliance may cause an
electric shock. Do not use a high pressure or steam
cleaner.
12


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Novy 6812 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Novy 6812 in the language / languages: English, German, Dutch, French as an attachment in your email.

The manual is 0,78 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Novy 6812

Novy 6812 User Manual - English, German, Dutch, French - 44 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info