Installation
B-1200
Menu
value
Description Remarks
0 Normal operation Factory settings
1 Normal operation
with ventilation
settings*
Allows the ventilation of the garage. In this mode, the garage door is
approximately 10 cm wide open. To start up the ventilation setting, press
the second button on the hand transmitter or use a DuoControl/Signal 111
(accessories) setting* that must be programmed in Menu 2.
The garage door can be closed at any time using the hand transmitter.
The garage door closes automatically after 60 minutes.
2 Partial opening of
side sectional door*
In this mode, the garage door is approximately 1 m wide open. To start up
the partial opening, press the second button on the hand transmitter or use a
button of DuoControl/Signal 111 (accessories)* that must be programmed in
Menu 2.
3 OPEN/CLOSE
buttons*
Impulse issue for OPEN command by pushing the rst button and for CLOSE
command by pushing the second button on the hand-held transmitter or the
button DuoControl/Signal 111 (accessories), which must be programmed in
menu 2.
4 Operation with
single-lane control**
Only possible in connection with the trafc light control A800 (accessories).
With the function Cancelling the green phase through the light barrier.
5 OPEN-CLOSE
operation with
single track
control**
Function like item 4, but without cancelling of the hold-open time. Function
process:
After pulsing in CLOSE position, the drive starts and the door moves into end
position OPEN. Another impulse entry during drive has no effect and the door
continues to open. After impulse entry in OPEN position, the door closes. On
impulse entry during closing, the door stops and starts again.
6 Automatic closing
(‘AR’)**
External safety facility. Impulse always causes an opening of the door.
After the hold-open time and warning time (setup menu A) the door closes
automatically.
An interruption of the photoelectric sensor during closing causes stop and
reverse direction. Interruption during opening drive has no effect.
7 Automatic closing
(‘AR’)**
Function as in point 6, however, an interruption of the photoelectric sensor
during open time causes early termination of open time and the warning time
starts.
8 Automatic closing
(‘AR’)**
Function as in point 7, however, an impulse during open time causes early
termination of open time and the warning time starts.
9 Automatic closing
(‘AR’)**
Same function as 8, but without early warning phase.
Remarks:
- *: The second button of the transmitter must be reset after changes in operating modes 1, 2 or 3.
- **: A photoelectric sensor must be installed.
3. Press the programming button (PROG button) (D).
In setting 0, 1, 2 and 5 value "0" is displayed. Menu end (poss. continue with force learning run).
In setting 6, 7, 8 and 9 value "A" is displayed. Continue with menu "A"
Warning:
Automatic door - Do not stop in the movement area of the door, because it may start
unexpectedly!
47


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Novoferm Novomatic 823S B1200 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Novoferm Novomatic 823S B1200 in the language / languages: English, German, Dutch, Danish, French as an attachment in your email.

The manual is 6,4 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info