Retain these installation, operating and maintenance instructions for the full duration of the operators service life!
OperatingInstructions
These Operating Instructions describe how to use
the prodct properly and safely. The safety advice and
information as well as the accident prevention and
general safety regulations for the field of application
must be complied with.
The garage door operator can be actuated by an
impulse generator such as hand transmitter, key
switch etc. It is only necessary to generate a short,
sharp impulse.
Operator starts up and causes the door to travel to
set open or closed travel limits.
The door stops.
Door continues to move but in opposite direction .
During adjustments, in the event of a power failure or
malfunctions, the door can be disengaged from the
operator by actuating the pull cord on the carriage
and then be operated manually.
If the door is to be operated manually over a longer
period of time, then the existing locking pin must be
inserted (see figure ). The door latches put out of
service for power operation must be refitted,
otherwise the door is not latched in the the closed
position.
In order to restore power operation, return the
locking pin to the parking position ( ) and put the
latches out of service.
After an impulse has been generated, the door
automatically latches with the door operator.
If the closing door encounters an obstruction, the
operator stops and causes the door to open to ist top
end-of-travel position in order to clear the
obstruction. During the last 2 seconds of the closing
cycle, the door only opens slightly, this being
sufficient to clear the obstruction but otherwise
preventing anyone from taking a look into the
garage.
If the opening door encounters an obstruction, the
operator stops immediately and reverses the
travelling direction for approx. one second.
Connection plan ( figure )
Wicket door contact STOPA
An open wicket door stops the operator immediately
or prevents it from starting up.
All persons using the gate system
mustbe shown how to operate it
properly andsafely.
Keep hand transmitters out of the reach
of children.
When the operator is being used, the
opening and closing phases must be
monitored. It must be ensured that
neither persons nor objects are located
within the gates range of travel.
Normal operation
Functional sequence
Quick release
12
a
Internalsafetydevice
External safety device
13
First impulse:
Impulse generated while door is moving:
Repeated impulse:
Solarmode
Maintenance/Checks
Make sure that there are no shadows from plants,
trees or buildings.
Remove dirt and leaves, and snow in winter, from the
module.
Check the drive display:
__________________________________
1 s 300 mA - 1 A
2 s 30 mA - 300 mA
4 s 3 mA - 30 mA
60 s 0 - 3 mA
The battery is maintenance-free.
Flash SolarpowerI
Cycle counter
Accu-Pack
L
The door system must be inspected
and tested by a specialist company
prior to initial operation and at least
once a year thereafter.
Monitoring the force limit
Caution!
The operator control unit features a dual-processor
safety system to monitor the force limit.
The integral force cut-out is automatically tested at
each travel limit.
The door system must be checked prior to initial
operation and at least once a year thereafter. In the
process, the force limiting device (figure 20) must be
tested!
If the closing force is set too
high, persons can be placed at risk of
injury or property could sustain damage.
Tthe force limit for the opening cycle can be adjusted
in menu stage 5, the force limit for the closing cycle
can be adjusted in menu stage 6.
The cycle counters stores the number of opening or
closing cycles performed by the operator.
In order to read out the meter, keep the
button pressed for 3 seconds until a number is
displayed. The display throws out the values
beginning from the highest decimal place down to
the lowest one after another. In the end, a horizontal
line is displayed. Example: 3456 cycles, 3 4 5 6 -
Light barrier (STOPB)
An interruption of the light barrier causes a stopping
and a reversal during the closing cycle. An
interruption of the light barrier during the opening
cycle makes no difference.
The lighting switches on automatically whenever a
start impulse is generated and switches off again
after the set time phase (factory setting approx. 60
seconds).
Programming further hand transmitters:
See menu stages 1 and 2 (figure 15 and 16).
Recharge theAkku-Pack before the first start-up and
after extended periods of no use. Charge the Accu-
Pack only with the supplied wall wart (power
adapter).
Insert the plug in theAccu-Pack socket.
Mind display:
LED red: Accu-Pack is being charged
LED blue: Accu-Pack is fully charged, trickle
charge.
Do not stop charging unless the battery pack
is fully charged.
Insert the drive plug in theAkku-Pack socket so that it
latches.
The drive is ready for immediate use.
The charge of the Accu-Pack is sufficient for 40 days
with 4 openings a day. The charge is depleted earlier
in extreme temperatures.
Example: The charge drops to 50% at -10°C.
Exhaustion is a cause of early battery failure.
Extended times of no-use of 6 months or more
deplete the battery.
Check the battery charge regularly and recharge in
time. We recommend the installation of a solar
module for easy recharging and extending the
battery life.
The battery charge is displayed every time the drive
is started:
Display Horn Battery charge
________________________________________
Continuous Charge voltage too high
tone
9 and 8 - Fully charged battery
7, 6, 5, 4 - Mean charge
3 1x briefly 30%, recharge
2 2x briefly 20%, urgent recharge
1 3x briefly 10%, operator can stop
0 Xx briefly <5%, no response from drive
Have system examined by a specialist!
Light is flashing
Press in the lever at the Accu-Pack socket and pull
the plug.
Lighting
Hand transmitter
Recharge the Accu-Pack
Connectingthedrivetothe Accu-Pack
Disconnectingthe Accu-Packfromthedrive
Battery mode
!
!
(1
(2
(2
(1
(2
2
3
21


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Novoferm Novomatic 423 Accu at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Novoferm Novomatic 423 Accu in the language / languages: English, German, Dutch, French, Spanish as an attachment in your email.

The manual is 3,7 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info