709180
12
Zoom out
Zoom in
Previous page
1/28
Next page
Unit Switch To save the battery on account of the increased The room in which the battery is located must be
The power converter can be switched on via the power dissipation on standby (approx. 1.8 W). well ventilated in accordance with the regulations.
unit switch to the left of the shockproof electric Do not mount the unit directly over heat sources
socket. If no AC consumers are being run off the Installation nor on easily ignitable materials. There must be a
unit, then the power converter is best switched off The SHS200 solar station must be installed near clear space of >100 mm above and below the unit.
the battery in accordance with its protection class.
Connection Schematic circuit diagram
The wiring and fuse protection of the system must conductor on the output side is not keep voltage drops on the line as low as
be carried out in accordance with the regulations permitted and will destroy the unit! possible. If the consumer connections are
on line protection or in accordance with the 2. Connect the battery to the designated screw incorrectly poled, these can still be destroyed
regulations applicable at the time. Before starting terminals -B +B, taking care to pole correctly to despite the fuse protection.
any wiring work, check for correct polarity and that avoid short circuits. In order to keep the voltage
the voltage of the individual system components, drop low and also the heating of the cable
i.e. of the solar station, solar modules, lead-acid connected with it, a flexible cable cross-section
battery, consumers, complies with that specified. If of 4.0 mm² is recommended. A corresponding
in doubt, consult your specialist dealer! When fuse should always be sited directly at the
installing the unit, it is important to observe the battery's plus pole in accordance with the
sequence described: regulations on line protection. The cables
connecting the battery to the station should not
1. Check to see whether the connected battery exceed a length of 3 m. The green LED on the
already has an earth connection. In this case, unit should light up. If not, check the fuse links
the minus pole must be earthed because the and make sure that voltage is being applied to
solar station is earthed internally. If not, connect the connection lead.
the unit's earth connection to your home's earth 3. If the station is so far working correctly, connect
connection. If you do not have an earth the solar module to the screw terminals -M +M,
connection, an earth connection must be taking care to pole correctly.
created in accordance with the regulations (e.g. 4. Connect the DC consumer to the screw
a ground rod). Under no circumstances is it terminals -L +L, taking care to pole correctly.
permitted to operate the unit unearthed Use cable of at least 1.5 mm² or in accordance
because operation of class 1 equipment in with the line protection. If the consumers are a
the presence of an error/failure can prove distance away from the solar station, you should
life-threatening. Earthing the neutral select a larger cable cross-section in order to
Wiring
- Caution: Take care to pole correctly! Follow the safety instructions!
GB
Retain these installation, operating and maintenance instructions for the full duration of the operator’s service life!
12


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Novoferm APS 230 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Novoferm APS 230 in the language / languages: English, German, Dutch, French, Spanish as an attachment in your email.

The manual is 1,57 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Novoferm APS 230

Novoferm APS 230 Additional guide - All languages - 1 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info