- All the safety devices, such as photocell (6), stop flashing.
Installation and Operating
wicket door contact, self-monitoring safety strip
Instructions for Traffic Light etc. are connected directly to the operator. Green and clearance phases
- Connect the impulse generator(s), inside and The duration of the green and clearance phases can
Controls
outside accordingly, to the traffic light controls. be set to requirements on the pots (17/18) for
All the above-mentioned products are available INSIDE and OUTSIDE (19/20).
Introduction
in the tormatic range of accessories.
These traffic light controls are suitable for operators
Adjustment range:
type 802 and 803. Please make sure that the
Connection plan with pre-assembled green phase 1 - 180 s, clearance phase: 1 - 120 s.
corresponding instructions for the operator are also
connection from the operator GTA803 to A800
to hand.
The system plug has to be wired according to the Description of function
The traffic light controls regulate the entry and exit of
illustration on the operator head. In order to open the door from the outside, the
vehicles in underground or collective garages.
corresponding button of the radio hand transmitter
Together with the garage door operator, they control
Prematurely terminated hold open time (21) or an external impulse generator, such as a key
the opening and closing of the door as well as the
On GTA803 menü 9 is set to number 4. switch, must be actuated. The operator opens the
necessary traffic light system. The operators
The green phase is prematurely terminated door. Both traffic lights (3 and 4) show RED. When
supplemented by these traffic light controls are
if the photocell connected at entrance STOP B the door is fully open, the traffic light on the entrance
connected via the wiring plug system (fig. C) or
of the garage operator control is interrupted. side changes to GREEN. You may now drive into the
conventional wiring system (fig. B), e.g. by key
garage. After the set green phase (1 - 180 s) has
switch (5), pull switch (8) or push button (7).
elapsed, the traffic light at the entrance changes
The traffic light controls can also be actuated via
Connection plan with pre-assembled back to RED. After a further set phase (clearance
radio.
connection from A800 to the control unit T100 phase 1 - 120 s) the door automatically closes again
Important note: radio devices and other impulse
The system plug has to be wired according to the and the traffic light system switches off 10 s later. If
generators used for opening the door may only be
illustration. when the door is closed, a request to drive through is
connected to the traffic light controls and not to the
received from both the inside and the outside, then
operator.
Adjusting the operation mode on the T100, menu the side on which the button was first pressed, gets
40: the green light. Once the set green and clearance
Installing the traffic light controls
5 - Traffic light operation (and menu 51:1) phases have elapsed, the other side then gets the
The traffic light controls (1) are in a suitable housing
6 - Traffic light operation with shortening of the go-ahead. Following another green and clearance
(9). They are mounted in the vicinity of the operator
hold open time phase, the door automatically closes again.
(2), at a max. distance of 7 m, at any chosen, easily
accessible location. All the necessary connecting
Installing the radio controls During times of high traffic, it is advisable to connect
cables are inserted into the housing of the traffic light
If the system is to be operated by radio, the receiver a timer to entrance STOP B. The door then stays
controls via the designated screwed cable gland.
module (optional) must be plugged into the plug-in open for the set phase and the traffic lights regulate
socket (12) and the aerial (n) connected. the entrance and exit. Waiting times are prevented
1. Traffic light controls
Attention: the position of the circuit board (1) must and the door mechanics are subjected to less wear
2. Operator
be above the drawn point. and tear.
3. Red/green traffic lights, inside
The garage door operator itself may not be operated
4. Red/green traffic lights, outside
by radio remote control! If whilst the door is closing a safety device (safety
5. Impulse generator, outside (e.g. key switch)
strip, photocell) comes into play, the door opens
6. Impulse generator, inside (e.g. push button
Programming the hand transmitter for the traffic again. Once the door has opened again fully, it
6a. Pull switch or motion sensor
light controls automatically recloses.
7. Emergency-STOP button
To program the hand transmitter (21), the housing (9) If via the safety devices a malfunction is reported five
8. Photocell
of the traffic light controls must be opened. times in succession, the door stays open and both
21. Hand transmitter
- Press the OUTSIDE radio code button (14), the traffic lights show RED. The malfunction must be
24. Safety edge (e.g. opto sesor)
corresponding LED (16) flashes. rectified and a new starting impulse given.
- Now actuate the hand transmitter. As soon as
Voltage supply 230V / 50Hz to L1
the code has been learned, LED (16) flashes
and N. The traffic lights (3) and (4) are
rapidly.
activated on 230V.
If the exit is also to be controlled via the hand
Connection diagram
transmitter:
a. Mains connection
- Press the INSIDE radio code button (15) and the
b. Green traffic light, inside
corresponding LED (16) flashes.
c. Red traffic light, outside
- Press the other button of the multi-channel hand
d. Green traffic light, outside
transmitter.
e. Red traffic light, outside
A maximum of 60 different hand transmitter
f. 24V AC max. 500mA for photocell
codes can be learned - when using both the
g. STOP B, enable for a time switch
inside and outside, this means a maximum of 30
h. Impulse generator, outside
hand transmitters. For ease of operation, we
i. Impulse generator, inside
recommend using a multibit hand transmitter
j. Status of open door from operator
when more than 10 transmitters are involved.
k. Status of closed door from operator
l. START impulse to operator
m.Bridge
n. Imput aerial
o. Wipe impulse ELTACO,
Deleting radio codes
- Press the OUTSIDE radio code button (14) and
keep it pressed for approx. 5 s until the LEDs
output for connection of
stairway automation, potential-free relay,
250 V AC /5A
1
2
2b
2c
GB
Retain these installation, operating and maintenance instructions for the full duration of the operator’s service life!
Function A800 GTA803 T100 Remark
START I brown/yellow F J1.1 / J1.4 required
Door close k green/red N X6.1 / X6.3 (Menu point 46=0) without door open message, ligth switch off after 90s.
Door open j green/blue M X5.1 / X5.3 (Menu point 45=1) required
STOP B g pink/grey H -
8


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Novoferm A800 III at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Novoferm A800 III in the language / languages: English, German, Dutch, French, Spanish as an attachment in your email.

The manual is 1,49 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info