EN
The on/off indicator (3), the temperature
indicator (5) and the temperature display (6)
will flash to show that the steam generator (2)
is switched off automatically. To switch on the
steam generator (2), lift and gently shake the
iron or press one of the buttons on the control
panel.
Cleaning and maintenance
Before you proceed, we need you to pay
attention to the following notes:
- Before cleaning or maintenance, remove
the mains plug from the wall socket and
wait until the appliance has cooled down.
- Do not immerse the appliance in water or
any other liquids.
Before you proceed, we would like you to
focus your attention on the following notes:
- Do not use aggressive or abrasive cleaning
agents to clean the appliance.
- Do not use sharp objects to clean the
appliance.
Regularly check the appliance for possible •
damage.
Regularly check the water reservoir for •
possible leakage.
Clean the appliance after each use:•
- Empty the water reservoir by draining
the water through the water drain point
into a sink.
- Remove limescale and other
contaminants from the soleplate with a
damp cloth and a non-abrasive cleaning
agent.
- Clean the housing of the iron with
a soft, damp cloth.
- Clean the housing of the steam
generator with a soft, damp cloth.
Replacing the anti-scaling cartridge
(fig. A & E)
The anti-scaling cartridge (25) must be replaced
when the replacement indicator (11) flashes.
Before you proceed, we need you to pay
attention to the following notes:
- Do not use the appliance without the
anti-scaling cartridge (25).
- When the anti-scaling cartridge (25) must
be replaced, you can still use the appliance
for your ironing purposes. Only use distilled
water in the water reservoir (19) when the
anti-scaling cartridge (25) must be
replaced. Do not use tap water in the
water reservoir (19) when the anti-scaling
cartridge (25) must be replaced.
Press the release button (23) to remove the •
water reservoir (19) from the appliance.
Remove the old anti-scaling cartridge (25) •
from the cartridge compartment (26).
If necessary, use kitchen paper to dry the •
cartridge compartment (26).
Place the new anti-scaling cartridge (25) •
into the cartridge compartment (26).
Place the water reservoir (19) into the •
appliance until the release button (23)
clicks into place.
While the replacement indicator (11) •
flashes, keep the on/off button (3) pressed
for 5 seconds to reset the anti-scaling
system. The replacement indicator (11)
goes off.
Rinsing out the boiler of the steam
generator (fig. A & F)
The steam generator (2) must be rinsed out
every month or after every 10 uses.
Before you proceed, we would like you to
focus your attention on the following notes:
- Before rinsing out the boiler of the steam
generator (2), remove the water reservoir
(19).
- Before opening the water drain point (21),
allow the steam generator (2) to cool
down for two hours.
Shake the steam generator (2) for a few •
seconds.
Place the steam generator (2) on its side so •
that the water drain point (21) points
upward.
Remove the cover (27) and loosen the •
screw (28).
Fill the boiler through the water drain •
point (21) with water (300 ml).
18


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Nova 320600 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Nova 320600 in the language / languages: English, German, Dutch, French, Italian, Spanish as an attachment in your email.

The manual is 1,4 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info