8.3.5 Crosstalk
For information about resolving crosstalk refer to the “Theory of Application” section in Diagnostic
Unit DU100 User Manual Document No. 895UM0001.
8.4 Functional Test
To test a detector, connect it to an inductive loop with a total inductance in order of 300 microhenries.
(This may be achieved in the workshop by winding (x) turns of wire on a non-metallic former of
diameter (y)).
X = 19 turns 0,25mm wire
Y = 238mm (9.4 inches)
Bring a small metal object approximately the size of a matchbox close to the loop coil. The following
will happen on detection:
The OUTPUT LED will light up.
The PRESENCE output relay will operate.
The PULSE relay will operate momentarily (approximately 150ms duration).
To check the sensitivity, presence time etc., use should be made a calibrated tester, which
compromises of a calibrated loop similar to the one described above with a moveable vane, which can
be moved over the loop at pre-determined heights.
This device together with the DU100 hand-held test instrument will allow comprehensive analysis of
the operating characteristics of the detector.
24


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Nortech PD-132 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Nortech PD-132 in the language / languages: English as an attachment in your email.

The manual is 0,84 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info