TECHNICAL DATA
Denition in accordance with
Constructive system
Nominal power in kW
Eciency in %
Smoke outlet diameter in mm
Chimney height ≥ (m) - dimension (mm)
Chimney draught in Pa (mm H2O)
Hourly wood consumption in kg / h (wood with 20% humidity)
CO measured at 13% oxygen in %
Exhaust gas emission in g/s – wood
Exhaust gas temperature in °C - wood
Average temperature of exhaust fumes in °C
Hearth opening size in mm (W x H)
Hearth size in mm (W x H x D)
Oven size in mm (W x H x D)
Type of grill Movable - at
Height in mm
Width in mm
Depth in mm
Weight in kg
Fire prevention safety distances Chapter FIRE SAFETY
Heatable m3 (30 kcal/h x m3)
(*) The proposed value are indicative. The installation must, in any case, be sized and veried according to the general calculation method in UNI
EN13384-1 or by another method of proven eciency.
(**) For those buildings in which the thermal insulation does not correspond to the instructions on heat protection, the heating volume of the product
is: favourable type of building (30 kcal/h x m3); less favourable type of building (40 kcal/h x m3); unfavourable type of building (50 kcal/h x m3).
With thermal insulation in accordance with the regulations regarding energy saving, the heated volume is greater. With temporary heating, in
the event of interruptions which last more than 8 hours, the heating capacity is reduced by about 25%.
THE DECLARED TECHNICAL DATA HAVE BEEN ACHIEVED BY BURNING BEECH WOOD CLASS A1” ACCORDING TO THE REQUIREMENT UNI EN ISO
172255 AND WOOD MOISTURE CONTENT LESS THAN 20%. BY BURNING A DIFFERENT KIND OF WOOD THE EFFICIENCY OF THE PRODUCT ITSELF
COULD CHANGE AND SOME SPECIFIC ADJUSTMENTS ON THE APPLIANCE COULD BE NEEDED.
How to set the machine to BOIL WATER
• Keep the ue gas register on the cooker function – LIGHTING / PLATE function.
• PRIMARY air CLOSED.
• SECONDARY air completely OPEN.
• Load wood as described in the manual (hourly load = hourly consumption).
How to set the machine to COOK BISCUITS
• Keep the ue gas register on the cooker function – OVEN USE.
• PRIMARY air CLOSED.
• SECONDARY air completely OPEN.
• Switch the cooker on with a moderate load of wood until the oven thermometer indicates 180 °C.
• Load a single piece of wood weighing 700 - 800 g one at a time and wait for it to burn completely before adding another.
• This keeps the oven temperature stable around 220 °C.
• Place the tray of biscuits in the 3rd shelf position for 10 minutes.
• Turn the tray halfway through cooking, if necessary.
ALASKA
EN 12815
1
12,0
88,6
150
(*) 4 - 200x200 Ø200
12 (1,2 mm H2O)
3,2
0,052 (648 mg/m3)
8,4
178,8
214,6
405 x 278
400 x 340 x 460
434 x 418 x 430
860
1307
705
350
344 (**)
29
29


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Nordica Alaska at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Nordica Alaska in the language / languages: English, German, French, Italian, Spanish as an attachment in your email.

The manual is 11.21 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Nordica Alaska

Nordica Alaska User Manual - Dutch - 28 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info