Temperature (Operating) +41°F to +104°F (5°C to +40°C)
Storage/Transportation -2F to +158°F (-3C to +70°C)
Device temperature will not exceed 41°C as measured
during a controlled environment test.
Humidity (Operating) 10% to 90% relative humidity,
non-condensing
Storage/Transportation 10% to 95% relative humidity,
non-condensing
Operating Altitude Up to 13,000 feet / 4,000 meters
Battery Life (Continuous) Approximately 2400 spot
checks based on ~21 hours
of operation using one AAA-
size alkaline battery, calculated
at 30 seconds per use.
Battery Life (Storage) 6 months minimum
Classifications per IEC 60601-1 / CSA 601.1/ UL 60601-1 30EM
Degree of Protection Type BF-Applied Part
Enclosure Degree of Ingress Protection IP33
Mode of Operation Continuous
This equipment complies with International Standard IEC 60601-1-2:2004 for electromagnetic
compatibility for medical electrical equipment and/or systems. This standard is designed to provide
reasonable protection against harmful interference in a typical installation. However, because of the
proliferation of radio-frequency transmitting equipment and other sources of electrical noise in
health care, home, and many other environments, it is possible that high levels of such interference
due to close proximity or strength of a source might disrupt the performance of this device.
This product complies with ISO 10993-1, Biological evaluation of medical devices – Part 1: Evaluation
and testing.
7077-000-01 GO2 Achieve User Guide.indd 21-22 4/3/2009 10:14:33 AM
13


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Nonin Go2 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Nonin Go2 in the language / languages: English as an attachment in your email.

The manual is 3,14 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Nonin Go2

Nonin Go2 User Manual - German, Dutch, French, Italian - 2 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info