ENGLISH - AINSTRUCTIONS FOR USE
CHARGING GEL/AGM (VRLA) BATTERIES
Charge the batteries each time the machine is used or when the Battery Charge Level Indicator (F8) is reading less than full.
WARNING!
Charge batteries in a well-ventilated area. If battery acid makes contact with your skin, ush the affected area with water for 5
minutes and seek medical attention.
Do not smoke while servicing the batteries.
FIGURE 9
13
15
32
33
F
F9
F8
When Servicing Batteries...
* Remove all jewelry
* Do not smoke
* Wear safety glasses, rubber gloves and a rubber apron
* Work in a well-ventilated area
* Do not allow tools to touch more than one battery terminal at a time
* ALWAYS disconnect the negative (ground) cable rst when replacing batteries to
prevent sparks.
* ALWAYS connect the negative cable last when installing batteries.
CAUTION!
Your voltage regulated lead acid (VRLA) battery will deliver superior
performance and life ONLY IF IT IS RECHARGED PROPERLY! Under
or overcharging will shorten battery life and limit performance. Be
sure to FOLLOW PROPER CHARGING INSTRUCTIONS! DO NOT
ATTEMPT TO OPEN THIS BATTERY! If a VRLA battery is opened, it
loses its pressure and the plates become oxygen contaminated. THE
WARRANTY WILL BE VOIDED IF THE BATTERY IS OPENED.
If your machine shipped with an onboard battery charger do the following:
1 Turn the Key Switch (A) OFF.
2 See Figure 9. Open the Control Panel Housing (13) set the Prop Rod (32).
3 Empty the Recovery Tank (15) using the Recovery Tank Drain Hose (30). Tip the
Recovery Tank (15) back for proper ventilation.
4 Unwind the electrical cord for the onboard charger near the front of the machine
and plug it into a properly grounded outlet. Refer to the OEM product manual for
more detailed operating instructions. NOTE: The Battery Charger Screen [4] will
be displayed on the Graphic Display (F) while AC power is applied to the onboard
charger (during which time all machine functions are disabled). This screen will
display Battery Charge Level Indicator (F8) and Battery Type (F9).
5 The Battery Charge Level Indicator (F8) will display full once the batteries are done
charging.
If your machine shipped without an onboard battery charger do the following:
1 Turn the Key Switch (A) OFF.
2 See Figure 9. Open the Control Panel Housing (13) set the Prop Rod (32).
3 Empty the Recovery Tank (15) using the Recovery Tank Drain Hose (30). Tip the
Recovery Tank (15) back for proper ventilation.
4 Disconnect the batteries from the machine and push the connector from the
charger into the Machine Battery Connector (33). Follow the instructions on the
battery charger. SERVICE NOTE: Make sure you plug the battery charger into the
connector that attaches to the batteries.
IMPORTANT: Make sure you have an appropriate charger for use on Gel cell
batteries. Use only “voltage-regulated” or “voltage-limited” chargers. Standard
constant current or taper current chargers MUST NOT be used. A temperature-
sensing charger is recommended, as manual adjustments are never accurate and
will damage any VRLA battery.
21


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Nilfisk SC1500 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Nilfisk SC1500 in the language / languages: English as an attachment in your email.

The manual is 16.82 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info