INSTRUCTIONS FOR USE
32401105(1)2004-04 A 9
If the filter is soiled by poisonous or otherwise dangerous
dust do not throw it away. Hand it to an authority, which is
authorised for the disposal of this type of waste.
Take particular care when replacing the main filter or the
complete filter and wear a P3-type mask.
Obtain a filter with the same characteristics as the old filter
and proceed as follows: (Fig. 17).
Fit the filter lock and the sealing ring of the old filter to the
new filter.
Insert the cage “4” and secure the filter using the plastic
strip “2” on the bottom of the filter.
Fit the filter rod in the filter shaking system and tighten the
screw.
Fit the upper cover on the filter unit.
Re-insert the filter unit into the machine.
Re-attach the suction pipe “1” in its original position.
Fix the clamp, which holds the filter unit on the machine.
ABSOLUTE FILTER
HEPA filter “1” must be installed when the vacuum must
operate in clean-room environments, when a high degree
of purity is required or when it must treat materials that are
dangerous for the operator.
This filter is installed in the filter compartment on the top of
machine, between the primary filter and the blower unit.
This allows the machines to achieve 99.995% MPP
efficiency at a particle size of 0.3 Micron, in retaining the
particles that escape the primary filter.
This value was gauged by means of the D.O.P. method.
CATEGORIES OF USE
Use in compliance with the standards.
Check which category your machine is suited for (see
identification plate).
The machine must not be used for several categories at
the same time, unless suitable accessories are used, such
as liquid kit if the machine is to be used for liquids.
Dust Class “L”
(Light hazard – defined by EN 60335-2-69).
This industrial vacuum is approved according to EN
60335-2-69 for category of use “L” and is fit to suck dry,
non flammable and non-toxic dust with MAK>1mg/m
3
values; the clean air is conveyed back into the place of
work.
Dust Class “M”
(Medium hazard – defined by EN 60335-2-69).
Suitable for removing hazardous, dry, not inflammable
dusts whose MAK limiting value is greater than 0.1 mg/m
3
.
Dust Class “H”
(High hazard – defined by EN 60335-2-69).
Suitable for removing hazardous, dry, not inflammable
dusts with all MAK limiting values as well as dry, not
inflammable dusts of carcinogenic substances. The
cleaned air is fed back to the workplace atmosphere.
Category of use ATEX
Industrial vacuum cleaners with the additional ATEX
machine type are tested and approved for the removal of
settled inflammable dusts.
Dusts with an extremely low minimal ignition energy (< 1
mJ) like toners, sulphur, aluminium powder or lead
stearate are excluded. In this case, operation requires a
special security consideration.
This vacuum must only be used to clean surfaces. It must
not be used to suction clean moving machines or powders
classified as liable to explode according to explosion
category G, in class ST3, nor inflammable liquids and
inflammable powders mixed with inflammable liquids.
ATTENTION!
The replacement of the filter is an important
procedure.
The filter must be replaced by another filter
with the same characteristics and the same
filter surface and category. If these rules are
not followed the vacuum cleaner may not
function correctly.
39


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Nilfisk IV040 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Nilfisk IV040 in the language / languages: English, German, Dutch, French as an attachment in your email.

The manual is 1,63 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Nilfisk IV040

Nilfisk IV040 User Manual - Danish - 60 pages

Nilfisk IV040 User Manual - Italian - 60 pages

Nilfisk IV040 User Manual - Polish - 60 pages

Nilfisk IV040 User Manual - Portuguese - 60 pages

Nilfisk IV040 User Manual - Swedish - 60 pages

Nilfisk IV040 User Manual - Spanish - 60 pages

Nilfisk IV040 User Manual - Norwegian - 60 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info