INSTRUCTIONS FOR USE
6 32401105(1)2004-04 A
Checking for proper connection
Check that all 3 phases are present. If the indicator light
“6” (yellow) is on, the phases are inverted, and need to be
changed according to the procedure stated below.
Proceed in the following way to check the turning direction:
1. If the yellow light “6” is on, when pressing the ON
button “4” the machine does not start.
2. Disconnect the machine from the mains socket and
invert two of the three live wires in the plug or in the
electrical box on the main switch (fig. 3).
3. Close the plug or the electrical box, connect it to the
mains socket and start the machine by pressing the
ON button “4” (fig. 4).
CONTROLS
1. Vacuum gauge to display filter clogging.
Indicates the degree of filter clogging in proportion to
the vacuum expressed in millimetres of water column.
Check when there are no accessories connected to the
machine.
When the indicator points to the red area, the filter
needs to be cleaned; if this is not sufficient, it must be
replaced.
2. Main switch.
Red on a yellow background
0 = Vacuum disconnected from the mains socket
1 = Vacuum electrically powered
3. POWER ON indicator (white light)
4. ON Button (green)
5. OFF Button (red)
6. Phase Indicator (yellow light).
STARTING AND STOPPING
Starting
Check that the machine has been effectively connected to
the mains socket. In particular, check that the main voltage
and frequency values correspond to those indicated on
the data plate (see fig. 1).
Fit the accessories “1” to the suction inlet.
Place the vacuum near the place of use, then lock the front
wheels by pressing levers downwards.
Set main switch “3” from position “0” (OFF) to position 1
(ON).
The vacuum is now ready for use.
Press the ON button “4” (green) to start the unit.
Stopping
Press the OFF button “5” (red) to stop the vacuum.
Turn main switch “3” from position “1” (ON) to position 0
(OFF).
This stops the vacuum for being electrically powered.
USING THE VACUUM
Correct use of the vacuum
Before using the machine, connect the suction pipe to the
inlet.
Keep long suction pipes as straight as possible.
Do not allow them to bend or twist as this will cause
excessive wear and clogging.
When the vacuum is powered, suction is created at the
pipe inlet and this sucks in the waste material.
This waste material passes through the pipe and
accessories through the inlet “4” until it reaches container
“6”, where a deflector “5” in the filtering chamber subjects
it to a centrifugal action causing the heavier solids to
deposit on the bottom of container “6”.
The primary filter will retain the lighter particles in the
airflow “3” as the air passes through it.
Lastly, the filtered air enters impeller “1” of the suction unit,
it is then exhausted through exhaust panel “2”.
Cleaning the primary filter
Vacuum gauge “1” is installed on the front part of the
vacuum (see fig. 4) and indicates the vacuum created
within the vacuum itself. This vacuum is expressed in
millimetres of water column. If the pointer is in the right
(green area), the filter will be in a good condition.
If the pointer swings to the left (red area), this means that
the filter is clogged and has a reduced filtering capacity.
In this case, it will be necessary to clean the primary filter.
Switch off the vacuum by pressing the OFF button “5” (red)
(fig. 4).
Operate the filter shaker handle “2” (fig. 7) several times in
order to detach the dust from the filter.
Wait a few minutes for the dust to deposit at the bottom of
the container, then empty this.
Clean the pipe, if this is the case.
ATTENTION!
Unauthorized personnel are forbidden to
use the vacuum.
The operator must check that all the guards
are mounted and that the safety devices are
installed and efficient.
NOTE
When the vacuum is not in use, leave main
switch “3” in position 0 (OFF) and the mains
isolator disconnected.
ATTENTION!
If the machine is used for fluids or wet
materials and fluid emerges from it, the
machine must be immediately switched-off,
cleaned and dried and all filters replaced.
NOTE
If the vacuum gauge “1” (fig. 7) is still in the
red area, the suction pipe, may be clogged,
and not the filter.
36


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Nilfisk IV040 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Nilfisk IV040 in the language / languages: English, German, Dutch, French as an attachment in your email.

The manual is 1,63 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Nilfisk IV040

Nilfisk IV040 User Manual - Danish - 60 pages

Nilfisk IV040 User Manual - Italian - 60 pages

Nilfisk IV040 User Manual - Polish - 60 pages

Nilfisk IV040 User Manual - Portuguese - 60 pages

Nilfisk IV040 User Manual - Swedish - 60 pages

Nilfisk IV040 User Manual - Spanish - 60 pages

Nilfisk IV040 User Manual - Norwegian - 60 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info