31965001. Replacement with the two speed PCB for 1200W motor. A-0.6.5.
22365700. Replacement of the on/off switch 9
22354400. Replacement of the on/off switch for parking
ASSEMBLY INSTRUCTIONS GM 200 / 300 / 400 & KING 500 SERIES
Instruction No. 82185900/00-11
To be performed by a skilled
or instructed person only !
Disconnect the vacuum cleaner
from the power supply before
starting the work!
1) Models with bag-full indicator:
Open the dust cover until it stops
and continue with a little pressure
by hand until it slides free of the
hinges.
Models with no bag-full indicator:
Open the dust cover and lift it out
of the hinges.
Remove filter with dust bag.
Remove the dust bag holder by
pressing bottom clip and ease the
holder out of the bottom. This
releases the hook at the container
wall.
2) To separate the top and bottom
housing and avoid scratches on
the parts, place tool no. 22361400
under the buffer.
Follow instruction 82361500
Remove the strap (12) by hand.
Lift up the buffer and remove the
top housing.
3) Free the cord with plug from the
terminal box in the top housing by
using a Pozi screwdriver no. 2 or in
old models press. it out by hand.
4) Remove and replace the
On/Off parking switch.
To release the switch, hold the
activator pin (5) with one hand and
release the switch (6) from the two
hooks and pull it away. Leave pin
(5) in its position.
Remove and replace the cords
to the switch (6).
Replace pin (5) by pushing it
downward to give the switch (6)
lever access to the hole in the
pin (5) and mount the switch (6).
Remove the cord reel and lock
the cord to the reel. Remove
internal wires and release the
on/off switch by pressing a
screwdriver under it.
Remove and replace the new
two-speed PCB and/or the
on/off switch and connect
wires.
5) NOTE:
GM200/300/400 SERIES ONLY.
Bend the terminal pins about 45
degrees
Refit in reverse order. Press the
buffer back in place by hand
after mounting the strap around
the housings.
R
5
5
6
WE
T
Q
12