609300
11
Zoom out
Zoom in
Previous page
1/19
Next page
11Original Instructions
EN
SC UNO/DUO
Therefore, it is important to follow the laws concerning the
removal of polluting and dangerous materials when repla-
cing spare parts or disposing of high pressure washer.
It is recommended that you bring the rejected parts to wa-
ste disposal areas or recycling plants that are approved
for the destruction of these types of materials.
Troubleshooting
You have chosen the best quality and therefore deserve the best service. To avoid unnecessary dis ap point ments, you
should check the following before contacting the nearest Nil sk service organisation:
Symptom Reason Action
Machine/pump will not start > A fuse has blown
> Power/plug not connected
> Thermal switches in motor activated
(red lamp ashes)
> Thermal relay switched off (red lamp
ashes)
> Oil shortage in pump
Change the fuse.
• Connect power/plug.
Let the motor cool. Start the machine
and check that the working pressure
is not too high and that the mains
voltage corresponds to the speci ca-
tions.
• Re ll with oil.
Fuses blow > Installation does not correspond to
the ampere consumption of the ma-
chine
Change to an installation correspon-
ding to the ampere consumption of
the machine at a minimum. Replace
the fuse.
Working pressure too low > Nozzle worn
> Wrong spray lance
> Reduction valve of spray lance not
adjusted to max. pressure.
> Nozzle partly clogged up
Replace the nozzle.
Replace the spray lance (see section
B4/B5).
Turn reduction valve completely
counter-clockwise.
Clean the nozzle (see section C.3).
Working pressure not steady > Water temperature too high
> Insuf cient water supply
> High pressure hoses too long
> Air in the system
> Water inlet lter clogged up
Lower the temperature of the inlet
water to max. temperature (see
Technical Speci cations).
Check water inlet lter. If that does
not solve the problem, the water
supply for the machine is insuf cient.
NB! Avoid long, thin hoses (min.
3/4").
Dismount high pressure extension
hoses and retry.
Extension hose max. 50 m.
NB! Avoid long extension hoses with
many couplings.
Vent the system (see section A.7).
• Clean lter (see sect. D.2)
No working pressure > Nozzle clogged up
> No inlet water
> High pressure cock of outlet point
open.
Clean nozzle (see sect. D.3)
Check that the shut off cock of the
water inlet is open. Check that the
water supply meets the requirements
(see section A.4)
Close all high pressure cocks not in
use.
Machine starts and stops > Leaky hose/ pipeline/spray handle Repair leak.
Machine stops > Oil shortage in pump. Red lamp
ashes
Top up with oil
11


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Nilfisk-ALTO SC UNO 7 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Nilfisk-ALTO SC UNO 7 in the language / languages: English as an attachment in your email.

The manual is 1,83 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Nilfisk-ALTO SC UNO 7

Nilfisk-ALTO SC UNO 7 User Manual - German - 19 pages

Nilfisk-ALTO SC UNO 7 User Manual - Dutch - 19 pages

Nilfisk-ALTO SC UNO 7 User Manual - French - 19 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info