609300
8
Zoom out
Zoom in
Previous page
1/19
Next page
8 Original Instructions
EN
SC UNO/DUO
Operating Instructions
This high pressure washer has been developed for pro-
fessional use within:
- agriculture, light industry, transport, building and con-
struction, service
Only use the high pressure washer for purposes de-
scribed in this manual.
Regarding the following sections:
A - Installation
B - Operation
C - Maintenance
please refer to pictures in front of the manual.
A - Installation
Before starting
DO READ SAFETY INSTRUCTIONS BEFORE USE!
Operating elements:
1. Water connection with lter
2. Main switch
3. Starting button
4. Stop button
5. Pressure gauge
6. Connection of high pressure hose
7. Electric cable
8. Service plug
9. Hour counter
10. Oil container
A.1 Temperature conditions
The machine should be installed in a frost-free room. This
applies to pump as well as pipelines incl. of outlet points.
Con cern ing outdoor outlet points it should be possible to
close and emp ty that part of the line which is exposed to
frost.
The maximum ambient temperature for the machine is
40°C.
A.2 Condition of distance
In consideration of the cooling system of the machine and
the accessibility of service, there must be free wall space
on both sides of the machine. To the right 500 mm at a
min i mum and to the left 150 mm at a min i mum.
SC UNO:
The recommended installation height for the machine
is max. 1700 mm measured from the upper edge of the
machine.
A.3 Wall mounting
SC UNO:
Only mount the machine on a solid wall construction
suited for the mounting of a ma chine. I.e. a concrete or
brick wall.
Do not mount the machine on a wall where it will cause
disturbances in neighbouring rooms (canteens, of ces
etc.).
SC DUO:
Place the machine on a plane oor.
Machine feet have been mounted under the machine.
These must be adjusted so that the machine stands sta-
ble. The feet may be bolted to the oor.
A.4 Water connection
The water connection is made through a exible hose
connected to the quick cou pling on the water inlet(s) (1)
of the machine.
The connection can be made to a water supply network
or an internal water sup ply. A shut-off cock should be
mounted on the water supply network in the immediate
vicini ty of the ma chine.
Max. water pressure: 10 bar
Min. water pressure: 1 bar
Max. water inlet temp.: See Technical Speci cations.
If there is a risk of running sands or other impurities in the
inlet water, a sand lter (50 micron) should be mounted
beyond the internal lter of the machine (for further con-
nection data see section Tech ni cal Speci cations).
Clean the water inlet lter (1) once a month.
SC DUO:
Water inlet hoses must be connected to the same water tap.
A.5 Mains power connection
Connect the machine to an approved safety switch.
Check voltage, fuse, and cables according to Safety
Instructions.
Connection data conc. power consumption can be taken
from the model tag of the machine.
A.6 High pressure connection
IMPORTANT: When connecting to a pipeline always use
a exible hose connection from the outlet of the machine
(pos. 6) - order no. 6300843. Contact your Nil sk distribu-
tor for further information.
The outlet of the machine can be connected to a pipeline
with xed outlet points, or standard high pres sure hoses
can be connected directly to the outlet of the machine.
It is recommended to let a service tech ni cian authorized
by Nil sk prepare the pipeline.
A.7 Venting
SC UNO:
Turn main switch (2) to position - 1 -. Open the outlet
point. Push the green starting button (3).
SC UNO 5M-L: Switch main switch to position - I -. Open
the outlet point.
Let the water run until all air has escaped from the pump
(even water ow).
In the case of a recently installed sys tem, or if the pipeline
and the pump have been emptied in any other way, the
system should be vented by starting the pump and then
8


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Nilfisk-ALTO SC UNO 7 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Nilfisk-ALTO SC UNO 7 in the language / languages: English as an attachment in your email.

The manual is 1,83 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Nilfisk-ALTO SC UNO 7

Nilfisk-ALTO SC UNO 7 User Manual - German - 19 pages

Nilfisk-ALTO SC UNO 7 User Manual - Dutch - 19 pages

Nilfisk-ALTO SC UNO 7 User Manual - French - 19 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info