72 Original Instructions
Poseidon 2
EN
WARNING! Always disconnect
the electrical plug from the
socket prior to maintenance or
cleaning.
To ensure a long and problem
free working life, please take
the following advice:
Wash off water hose, high
pressure hose, spray lance
and accessories before
mounting.
Clean the connectors of dust
and sand.
Clean the nozzles.
Any repair should always be
made in an authorized work-
shop with original spare parts.
7 Maintenance
7.1 Cleaning of water inlet
lter
Clean the water inlet fi lter regu-
larly once a month or more fre-
quently according to use. Care-
fully loosen the fi lter with a pair
of pliers and clean it. Check that
it is intact before re-mounting it.
The inlet fi lter must always be
tted inside the water inlet pipe
to fi lter out sand, limestone and
other impurities, as they will
damage the pump valves.
CAUTION: Failure to fi t the fi lter
will invalidate the guarantee.
7.2 Cleaning of nozzle A clogging up in the nozzle
causes a pump pressure which
is too high. This is why cleaning
is required immediately.
1. Stop the machine and dis-
connect the nozzle.
2. Clean the nozzle. IMPOR-
TANT: The cleaning tool (11)
should only be used when
the nozzle is detached!
3. Flush the nozzle backwards
with water.
7.3 Cleaning of machine
vents
The machine should be kept
clean so as to let cooling air
7.4 Greasing of couplings
To ensure easy connection and
that o-rings do not dry up, the
pass freely through the ma-
chine vents.
couplings should be greased
regularly.
72


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Nilfisk-ALTO Poseidon 2 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Nilfisk-ALTO Poseidon 2 in the language / languages: Danish, Italian, Portuguese, Swedish, Spanish, Norwegian, Finnish as an attachment in your email.

The manual is 8.34 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Nilfisk-ALTO Poseidon 2

Nilfisk-ALTO Poseidon 2 User Manual - English - 23 pages

Nilfisk-ALTO Poseidon 2 User Manual - German - 25 pages

Nilfisk-ALTO Poseidon 2 User Manual - Dutch - 19 pages

Nilfisk-ALTO Poseidon 2 User Manual - French - 26 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info