1)
Options / model variants
Original instructions
NEPTUNE 4 FA
3.8 Fill up fuel tank
With the machine cold:
1. Pour fuel (fuel oil EL,
or Diesel oil DIN 51 603)
into the fuel tank.
Bio-Diesel can be used, see
notes in chapter 1).
The fuel must be free from con-
tamination.
Tank capacity see chapter 9.4
Technical data.
NOTE!
At temperatures below 8° C, the fuel
oil begins to solidify (paraffin precip-
itation). This can lead to difficulties
in starting the burner. Before the
winter period either add a solidifica-
tion point / flow improver (available
from the fuel oil trade) to the fuel or
use winter diesel fuel.
3.9 Connecting the high
pressure hose
3.9.1 Machines with high
pressure hose reel
1. Put the quick connector of
the high pressure hose onto
the nipple on the axle.
3.9.2 Machines without high
pressure hose reel
1. Put the quick connector of
the high pressure hose onto
the nipple on the cleaner.
3.7 Antiscale
The Nilfisk Alto Antiscale dosing
system is set by the factory.
To adjust the water hardness we
recommend that the inlet water
is tested accordingly.
Use the schematic to find the
right dosage of No Scale/anti
stone and water, and add the
mixture to the antiscale tank.
Machine flow L/h Pump size ml/h ˚dH ˚f ˚e Dosage
800 35 0-12 0-21,5 0 - 15 1:1 = 17ml/h
800 35 12-30 21,5 - 53,7 15 - 37,5 Pure = 35ml/h
900 35 0-12 0-21,5 0 - 15 1:1 = 17ml/h
900 35 12-30 21,5 - 53,7 15 - 37,5 Pure = 35ml/h
1000 35 0-12 0-21,5 0 - 15 1:1 = 17ml/h
1000 35 12-30 21,5 - 53,7 15 - 37,5 Pure = 35ml/h
9


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Nilfisk-ALTO NEPTUNE 4 FA at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Nilfisk-ALTO NEPTUNE 4 FA in the language / languages: English as an attachment in your email.

The manual is 1,79 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Nilfisk-ALTO NEPTUNE 4 FA

Nilfisk-ALTO NEPTUNE 4 FA User Manual - German - 22 pages

Nilfisk-ALTO NEPTUNE 4 FA User Manual - Dutch - 22 pages

Nilfisk-ALTO NEPTUNE 4 FA User Manual - French - 22 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info