608957
6
Zoom out
Zoom in
Previous page
1/22
Next page
4
1)
Options / model variants
Original instructions
NEPTUNE 4 FA
hose or cord over the chimney.
Danger for persons, risk of
overheating and fi re.
Electrical equipment
CAUTION!
Never spray electrical equip-
ment with water: risk of elect-
trical shock and short-circuit.
The cleaner may only be con-
nected to a correctly installed
plug socket.
Switching on the cleaner may
cause voltage fl uctuations.
Voltage fl uctuations should not
occur if the impedance at the
transfer point is less than 0.15
If in doubt ask your local electric-
ity supplier.
Maintenance and repair
Warning
The cleaner must be discon-
nected from its power source
during cleaning of the ma-
chine, maintenance, when re-
placing parts or converting the
machine to another function.
Carry out only the maintenance
operations described in the
operating instructions. Use only
original Nilfi sk-ALTO spare parts.
Do not make any technical modi-
fications to the high-pressure
cleaner.
Ensure that the machine is regu-
larly serviced by authorized Nil-
sk-ALTO dealers in accordance
with the maintenace plan. Failure
to do so will void the warranty.
CAUTION!
High-pressure hoses, ttings
and couplings are important
for the safety of the cleaner.
Use only high-pressure parts
approved by the manufac-
turer!
The power cord must not differ
from the version specifi ed by the
manufacturer and may only be
changed by an electrician.
Please contact your local author-
ized Nilfi sk-ALTO equipment dis-
tributor for all other maintenance
or repair needs!
Testing
The cleaner conforms to the Ger-
man „Guidelines for Liquid Spray
Jet Devices“. The high-pressure
cleaner must be subjected to a
safety examination in accord-
ance with the „Accident Preven-
tion Regulations for Working
with Liquid Spray Jet Devices“
as required, but at least every
12 months, by an authorised
inspector.
After all repairs or modifica-
tions to electrical equipment,
the protective conductor resist-
ance, the insulation resistance
and the leakage current must
be measured. Furthermore, a
visual inspection of the mains
power cord, a voltage and current
measurement and a function test
must be carried out. Our after-
sales service technicians are
at your disposal as authorised
inspectors.
The complete „Accident Preven-
tion Regulations for Working
with Liquid Spray Jet Devices“
are available from the Carl Hey-
manns Verlag KG, Luxemburger
Strasse 449, 50939 Cologne or
from the appropriate associa-
tion of employers’ liability insur-
ances.
The pressure-bearing parts of
this high-pressure cleaner have
been manufactured in accord-
ance with § 9 of the German
Pressure Vessels Ordinance
and successfully subjected to a
pressure test.
Bypass valve
The pressure is reduced by
means of a "bypass valve" which
returns water to the inlet side of
the pump at a minimum pressure.
The point at which this occurs is
set and sealed at the factory and
must not be adjusted.
2 Description
2.1 Purpose
This high-pressure cleaner has
been designed for professional
use. It can be used for cleaning
agricultural and construction
equipment, stables, vehicles,
rusty surfaces, etc.
The cleaner has not been ap-
proved for cleaning surfaces
which comes into contact with
food.
Chapter 5 describes the use of
the high-pressure cleaner for
various cleaning jobs.
Always use the cleaner as de-
scribed in these operating in-
structions. Any other use may
damage the cleaner or the sur-
face to be cleaned or may result
in severe injury to persons.
6


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Nilfisk-ALTO NEPTUNE 4 FA at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Nilfisk-ALTO NEPTUNE 4 FA in the language / languages: English as an attachment in your email.

The manual is 1,79 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Nilfisk-ALTO NEPTUNE 4 FA

Nilfisk-ALTO NEPTUNE 4 FA User Manual - German - 22 pages

Nilfisk-ALTO NEPTUNE 4 FA User Manual - Dutch - 22 pages

Nilfisk-ALTO NEPTUNE 4 FA User Manual - French - 22 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info