Cannot select a computer connected to a Slave.
Make sure that the Slave’s Console port is connected to one of the Master’s PC ports.
Only ports PC 1 to PC 8 can be connected to Slaves, even if the Master switch has 16 PC
ports.
Keyboard strokes are shifted.
Press both Shift keys.
Certificate warning shown while connecting via HTTPS.
It is normal for a warning dialog to be shown when connecting via HTTPS. The SSL
certificate we use is created when the unit is first produced. It does not contain the correct
hostname (subject name) because you can change the hostname as required. Also, it is
not signed by a recognized certificate authority (CA) but is signed by our own signing
authority. For more details, refers to “Appendix A: About Security Certificate Warnings.” on
page 32.
Windows XP doesn't awake from standby mode.
This is possibly a Windows XP problem. Try not to move the mouse while XP goes into
standby mode.
The terminal connection to NewStar Digital KVM via IP for initial configuration
cannot be established.
Check that the Null Modem cable connected to DCE Serial Port on the NewStar Digital
KVM via IP and terminal software is set to the following line parameters:
Connection speed: 115200 bps
No. of bits: 8
Parity: None
Stop bits: 1
Flow Control: None
Connect computer to the NewStar Digital KVM via IP and power this computer on. Power
on the NewStar Digital KVM via IP while pressing the ESC key on the keyboard
connected to it? This will switch the DCE Serial Port 1 to Configuration Login setting even
if it was set to Pass-through or Modem.
Also, Windows HyperTerminal has a bug: if you change baud rates while connected. the
screen is updated but the hardware is still at old baud rate; hang up and reconnect (using
icons at top of screen) to make new settings take effect.
If my network has a firewall, what setting do I use on the IP Extender to open a port
into the network?
You shouldn't change any settings in the NewStar Digital KVM via IP, but you should
open port 22 for both outbound and inbound connections in your firewall.
Port 22 only needs to be opened for inbound connections. You must use SSH tunnel to
connect to machine; tunnel to port 127.0.0.1:5900 for VNC protocol, and 127.0.0.1:80 for
HTTP (web) control.
OR, instead of SSH client, open ports 443 and 15900 (inbound) for HTTPS and encrypted
VNC protocol. Then click always on the "encrypted" link. This is easier because you don't
need to setup SSH tunnels.
36


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Newstar NS-1641HDI at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Newstar NS-1641HDI in the language / languages: English as an attachment in your email.

The manual is 1,73 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info