Factory Default Settings
You can return the switch to its factory settings. Use the end of a paper clip or some other similar object to
press and hold the Factory Defaults button on the front panel of the switch for four seconds.The switch
resets and returns to the factory settings that are shown in the following table.
Table 7. Factory default settings
SettingFeature
passwordSwitch password
192.168.0.239 (if the switch is not connected to a network with a DHCP server)IP address
255.255.255.0Subnet mask
EnabledDHCP mode
EnabledUPnP
EnabledBonjour
EnabledNSDP
EnabledIGMP snooping
None configuredLAGs
Disabled. If enabled, by default, all ports are members of VLAN 1.VLANs
Disabled. If enabled, by default, the Class of Service (CoS) value is 6.Voice VLAN
Enabled802.1p/DSCP-based QoS
DisabledPort-based QoS
DisabledRate limiting
DisabledBroadcast filtering
EnabledLoop prevention
DisabledPower saving mode
AutonegotiationPort speed
DisabledFlow control
DisabledPort mirroring
Factory Default Settings and Technical Specifications
65
12- or 24-Port 10-Gigabit/Multi-Gigabit Switch Models XS512EM and XS724EM
65


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Netgear XS512EM at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Netgear XS512EM in the language / languages: English as an attachment in your email.

The manual is 1,55 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Netgear XS512EM

Netgear XS512EM Installation Guide - English - 2 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info