Configuring System Information
57
GS752TP, GS728TP, and GS728TPP Gigabit Smart Switches
The following screen displays:
Note: You can also access the LLDP Configuration screen by selecting
System > LLDP > Advanced > LLDP Configuration.
2. Configure the following LLDP settings:
TL
V Advertised Interval. Specify the interval at which frames are transmitted. The
default is 30 seconds, and the valid range is 5–32768 seconds.
Hold Multiplier. Specify multiplier on the transmit interval to assign to
Time-to-Live
(TTL). The default is 4, and the range is 2–10.
Reinitializing Delay. Specify the delay before a reinitialization.
The default is 2
seconds, and the range is 1–10 seconds.
T
ransmit Delay. Specify the interval for the transmission of notifications. The default
is 5 seconds, and the range is 5–3600 seconds.
3. T
o change the LLDP-MED properties in the Fast Start Duration field, specify the number of
LLDP packets sent when the LLDP-MED Fast Start mechanism is initialized.
This occurs when a new endpoint device links with the LLDP-MED network connectivity
device.
The default value is 3, and the range is from 1–10.
4. Click APPLY.
Configuration changes take effect immediately.
57


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Netgear GS728TPP at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Netgear GS728TPP in the language / languages: English as an attachment in your email.

The manual is 14,95 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Netgear GS728TPP

Netgear GS728TPP Installation Guide - English - 2 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info