Monitor the System
378
Insight Managed 8-Port Gigabit Ethernet Smart Cloud Switch with 2 SFP Fiber Ports
If you do not know the IP address of the switch, see Access the Switch on page 13.
The login window opens.
4. Enter the switch’s password in the password field.
The default password is password. If you added the switch to a network on the Insight
app before and you did not yet change the password through the local browser interface,
enter your Insight network password.
The System Information page displays.
5. Select Monitoring > Logs > Memory Log.
The Memory Log Configuration page displays.
6. Select one of the following Admin Status radio buttons:
Enable. Enable system logging.
Disable. Prevent the system from logging messages.
7. From the Behavior menu, specify the behavior of the log when it is full.
Wrap. When the buffer is full, the oldest log messages are deleted as the system logs
new messages.
Stop on Full. When the buffer is full, the system stops logging new messages and
preserves all existing log messages.
8. From the Severity Filter menu, select one of the following severity levels:
Emergency (0). System is unusable.
Alert (1). Action must be taken immediately.
Critical (2). Critical conditions.
Error (3). Error conditions.
Warning (4). Warning conditions.
Notice (5). Normal but significant conditions.
Informational (6). Informational messages.
Debug (7). Debug-level messages.
Note: A log records messages equal to or above a configured severity
threshold.
9. Click the Apply button.
Your settings are saved.
The Memory Log table displays on the Memory Log Configuration page.
The Total number of Messages field displays the number of messages the system logged
in memory. Only the 200 most recent entries are displayed on the page.
The rest of the page displays the Memory Log messages. The format of the log message
is the same for messages that are displayed for the message log, persistent log, or
378


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Netgear GC110 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Netgear GC110 in the language / languages: English as an attachment in your email.

The manual is 1,84 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info