571179
4
Zoom out
Zoom in
Previous page
1/48
Next page
4
1. INTRODUCTION
IMPORTANT! All local regulations, including those
that refer to national or European regulations, must
be applied when installing this device.
The way the stove is installed will decisively affect
safety issues and its correct operation.
It is important to install the stove correctly. For the
correct installation of the stove and chimney, we
recommend the installation be performed by a
professional.
Please read this entire manual before you install and
use your new room heater. Failure to follow
instructions may result in property damage or bodily
injury.
2. INSTALLATION
If your stove is not properly installed, injury or property
damage may result. For your safety, follow the
installation directions. Contact local building or fire
officials about restrictions and installation
requirements in your area.
Warning: Do not connect this unit to a chimney flue
serving another appliance. The unit must be installed
according to all local codes. Installations other than
those specifically covered herein have not been
confirmed by test and are not covered by the
certification
2.1. Chimney.
The chimney is a vital part of your stove installation. A
properly built masonry chimney will assure a
consistent draft under a variety of weather conditions.
(A smoking stove is almost always caused by a chimney
problem)
All chimneys must be installed either according to the
local building codes in the case of a masonry chimney
or according to the chimney manufacturer’s
instructions in the case of a factory-built metal
chimney. See the chimney manufacturers’ instructions
for exact specifications
Existing chimneys must be inspected before installing
your stove. Consult your local building department for
chimney code requirements. A masonry chimney
should have a code approved liner. This liner must not
have broken or missing pieces. Some non-code
masonry chimneys may be brought up to code by being
relined. (Consult your dealer or qualified chimney
sweep.) Factory-built metal chimneys should also be
inspected, first for creosote deposits (which should be
removed), and then for integrity of the stainless steel
liner. Look for obvious bulges in the lining which may
indicate the need to replace that section (use a bright
flashlight). Also inspect the attic to see that the
chimney has proper clearance to combustible framing
members.
The chimney or vent shall be designed and
manufactured to develop a flow sufficient to
completely remove all flue and vent gases to the
outside atmosphere. The venting system shall satisfy
the draft requirements of the connected appliance in
accordance with the manufactures instructions. The
location, section and height of the chimney condition
the draft.
2.1.1. Chimney Height requirements.
We recommend that the chimney be:
1. at least 100 cm higher than the highest part of the
roof opening through which it passes,
2. and at least 60 cm higher than any part of the roof
within 300cm, measured horizontally.
Fig. 1
2.1.2. Draft requirements
The appliance is merely one component of a larger
system. The other equally important component is the
chimney. This is necessary for achieving the required
flow for safety removing unwanted combustion by-
products from the appliance. If the chimney design
does not promote these ends, the system may not
function properly.
The recommended draft requirements for your stove is
no less than 15 pa (-0.048”) and no greater than 25
pa (-0.12”).
OPERATION OF YOUR STOVE WITH A DRAFT GREATER
THAN 30 Pa (-0.14”) CAN POSSIBLY CAUSE DAMAGE
TO THE STOVE AND VOID THE WARRANTY.
2.1.3. Summary of rules
We shall now provide a summary of the rules that
should be followed when building a chimney:
Use resistant and non-combustible materials
for the connection between the appliance and
4


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Nestor Martin S33 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Nestor Martin S33 in the language / languages: English, Spanish as an attachment in your email.

The manual is 4.82 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Nestor Martin S33

Nestor Martin S33 User Manual - English - 31 pages

Nestor Martin S33 User Manual - Dutch, French - 25 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info