Floor Protection Requirements
A non-combustible floor protector (hearth extension) must be installed under the unit.
Check with local building authorities as to what other materials are acceptable.
The floor protector must extend:
1. Beyond the front door, a minimum of 16 inches (400 mm) in USA and 18 inches (450 mm) in Canada. See
measurement “B” on the floor protection drawing below.
2. On both sides of the unit, a minimum of 5 inches (125 mm) in USA and 8 inches (200 mm) in Canada. See
measurement “C” below.
3. On the back of the unit, a minimum of 0” (0 mm) in USA and 8 inches (200 mm) in Canada. See
measurement “A” below.
Notice: In case of installation with horizontal pipe, the floor protection must be extended beyond the back of the
appliance under the chimney connector and 2” (50 mm) beyond each side of the chimney connector.
Minimum requirements for floor protection on combustible floors
Types of Chimneys
The Chimney is a vital part of your stove installation. Your stove must be connected to either a code-approved
masonry chimney (a flue liner may be required), or a 6-inch diameter factory built chimney complying with the UL
requirements for Type HT chimneys (regulation UL 103 and ULC S629).
All chimneys must be installed either according to the local building codes in the case of a masonry chimney or
according to the chimney manufacturer’s instructions in the case of a factory-built metal chimney. See the chimney
manufacturers instructions for exact specifications. An oversized chimney may result in less than optimum
performance. Installations into a large, masonry chimney may require a liner to improve performance.
Chimney Inspection
Existing chimneys must be inspected before installing your stove. Consult your local building department for chimney
code requirements. A masonry chimney should have a code-approved liner. This liner must not have broken or
missing pieces. Some non-code masonry chimneys may be brought up to code by being relined. (Consult your dealer
or qualified chimney sweep.) Factory built metal chimneys should also be inspected, first for creosote deposits (which
would be removed), and then for integrity of the stainless steel liner. Look for obvious bulges in the lining, which may
indicate the need to replace that section (use a bright flashlight). Also inspect the attic to see that the chimney has
proper clearance to combustible framing members.
6
6


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Nestor Martin R33 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Nestor Martin R33 in the language / languages: English as an attachment in your email.

The manual is 2,25 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Nestor Martin R33

Nestor Martin R33 User Manual - Dutch, French - 25 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info