Toestelgegevens2
2.15 Elektrisch schema
Afb. 9 Elektrisch schema
[1] branderautomaat
[2] printplaat 3-wegklep1)
[3] zekering
[4] pomp
[5] ventilator
[6] transformator
[7] gloeiplug
[8] gasregelblok
[9] 3-wegklep
[10] KIM (Ketel Identificatie Module)
[11] druksensor
[12] ionisatie
[13] aarde
[14] connector (loze aansluiting)
[15] bruin - voedingskabel L = 230 VAC
[16] blauw - voedingskabel N = 0 VAC
[17] geel-groen - aardekabel
[18] aanvoertemperatuursensor
[19] safetytemperatuursensor
[20] retourtemperatuursensor
[21] turkoois - externe 3-wegklep, 24 VAC/ max. 6 VA
[22] grijs - externe (solar) bewaartemperatuursensor of
Solarthermostaat
[23] blauw - buitentemperatuursensor
[24] rood - extern schakelcontact (NC), doorgelust indien niet aange-
sloten
[25] oranje - ModuLine thermostaat/ EMS-bus
[26] groen - aan-uitregeling
[27] bedieningspaneel
[28] boilersensor Nefit TopLine AquaPower HRC II
[29] aansluitconnector oplaadboilersensor Nefit TopLine AquaPower
Plus HRC II
[30] flowsensor1)
[31] warmwateruitstroomsensor1)
[32] bewaartemperatuursensor1)
[33] aansluitstrook Nefit TopLine HR II en Nefit TopLine AquaPower
Plus HRC II-toestellen
[34] grijs - boiler(laad)pomp 230 VAC, max. 250 W
[35] voeding 230 VAC, 50 Hz, netstekker
[36] boilerlaadpomp Nefit TopLine AquaPower Plus HRC II
6 720 801 234-009.2
F1
F2
2020
12 13
36
15
16
17
17
15
16
I
1
2
3
4
5
6
7
8
9
10
11
18
19
34
33
35
NL
230V
IN
NL
14
27
32
31
30
28
32
31
30
29
21
22
23
24
25
26
EMS
EMS0V
24V
1) Alleen bij combi-toestellen.
10


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Nefit TopLine AquaPower Plus HRC II at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Nefit TopLine AquaPower Plus HRC II in the language / languages: Dutch as an attachment in your email.

The manual is 4,72 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Nefit TopLine AquaPower Plus HRC II

Nefit TopLine AquaPower Plus HRC II User Manual - Dutch - 12 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info