662861
114
Zoom out
Zoom in
Previous page
1/124
Next page
Bijlage8
Nefit B.V. • http://www.nefit.nl/professioneel Wijzigingen op grond van technische verbeteringen voorbehouden!
114 Service-instructie Nefit SmartLine HR(C) en Nefit SmartLine Basic HR(C) • uitgave 01/2009
frame 367 Elektrisch schema Nefit SmartLine Basic HR(C)
38
39
70
62
55
61
11
12
20
2
Bedrijfsschakelaar
BC 10
connector
2
3
Drieweg-
klep
Pomp
PE LN
M
P
5
6
Transformator
Gloei-
plug
N
Ventilator
Gas-
regel-
blok
Ionisatie
Safetysensor
Retoursensor
Netstekker
230 VAC 50 Hz
Nefit buiten-
temperatuursensor
Externe boilersensor
Aan/Uit-thermostaat
(potentiaalvrij)
Aarde
53
79
23
67
68
76
12
13
14
45
17
49
11
10
28
1
81
27
52
25
3
4
7
PE
L
N
80
9
44
16
6 7 851 2 3 4
L
N
PE
L
N
4
3
2
1
8
15
16
1
Extern schakelcontact
Bijv. vloerverwarming
13
14
Aanvoersensor
70
21
81 pin Laagspanningsconnector
28
55
Pin 81
Pin 1
16 pin Hoogspanningsconnector
Montagevoet UBA 3
KIM
16 pin Hoogspanningsconnector
81 pin Laagspanningsconnector
Externe
driewegklep
24 VAC/max. 6 VA
Geldt alleen voor:
Nefit SmartLine Basic HRC 24/CW3
Nefit SmartLine Basic HRC 24/CW4
Aarde
230 VAC
230 VAC
230 VAC
24 VAC
0 VAC
24 VAC
24 VRAC
230 VAC
Schakelcontact
24 VAC
10 VAC
10 VAC
230 VAC
0 VAC
50
78
Nefit ModuLine
kamerthermostaat
2
2
Geldt alleen voor Nefit SmartLine Basic HR24
2
1
3 4
5 6
7 8 9 10 11
12
13
groen oranje rood blauw grijs turkoois
(licht blauw)
1 - 2 1 - 2 1 - 2 1 - 2 1 - 2 1 - 2 - 3
24 Vac
0 Vac
1 2
Aansluiten door erkende vakspecialisten
RCC
1 2
1
2
3
1
M
PE
L
N
2
3
1
231541
5
4
2
3
1
23154
7
6
2
1
3
1
L
2
3
1
34
43
8
35
60
33
74
75
57
58
77
26
37
36
64
63
53
79
23
1
2
3
4
5
6
7
8
9
10
11
12
13
Pin 1
Pin 16
1
1
Aansluitkast
Flow-
sensor
2
3
1
Druk-
sensor
Rookgasthermostaat
Branderthermostaat
114


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Nefit SmartLine Basic HRC 24-CW4 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Nefit SmartLine Basic HRC 24-CW4 in the language / languages: Dutch as an attachment in your email.

The manual is 8,61 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Nefit SmartLine Basic HRC 24-CW4

Nefit SmartLine Basic HRC 24-CW4 User Manual - Dutch - 36 pages

Nefit SmartLine Basic HRC 24-CW4 Installation Guide - Dutch - 72 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info