613806
108
Zoom out
Zoom in
Previous page
1/112
Next page
108
Wijzigingen op grond van technische verbeteringen voorbehouden!
6 720 804 119 (2012/06)
Bijlage13
Nefit B.V. • http://www.nefit.nl
Nr. Symbool Beschrijving
1 DNDM 1-2: ingang soft draaien
1-3: ingang extern signaal
2 CN51 Externe uitgangssignalen (compressorbedrijfssignaal, storingsmeldingen)
3 CN52C Aansluiting op het ontstoringsfilter
4 CN4 Stuursignalen op de inverter-printplaat
5 SV2 Bypassventiel
6 21S4 4-weg-ventiel
7 CN2 Aansluiting op de voedingsspanningsprintplaat van de buitenunit
1-5: stuursignalen aan de printplaat (0 — 5 V DC)
2-5: Zero-Cross signaal (0 — 5 V DC)
3-4: niet gebruikt
6-5: 16 V DC
7-5: 16 V DC
8 CNAC 2-4: voedingsspanning voor de printplaat (220 — 240 V AC)
1-3: voedingsspanning van de stuurkabel naar de binnenunit
(220 — 240 V AC)
9 CNS S1-S2: 220 — 240 V AC
10 +/- Voedingsspanning voor communicatie D71 V, spanning 24 V DC
11 CNDC 280 V DC (inverter-printplaat 140 V)
12 CNF1, CNF2 Aansluiting voor ventilatormotoren
1-4: 280 V DC
5-4: 15 V DC
6-4: 0 — 6,5 V DC
7-4: 15 V DC bij stilstand, 7,5 V DC bij rotatie, 0 — 15 V gepulsd
13 V
SP
Spanning van de pins aan C5A, C5B: 0 V DC bij stilstand, 1,5 V DC bij rotatie
14 V
FG
Spanning tussen de rechter pins op PC5C en PC5D, pin 3 en pin 4 (idem als CNF1)
15 TH33 Temperatuursensor (vloeistofleiding)
16 TH32 Temperatuursensor (compressorhuis)
17 63H Hogedrukschakelaar
18 TH7/6 Temperatuursensor (warmtewisselaar, 2-fase mengsel)
19 TH3 Temperatuursensor (vloeistofleiding)
20 TH4 Temperatuursensor (heet gas)
21 LEV-A, LEV-B Lineaire expansieventielen
22 CNVMNT M-NET-adapter (optie)
23 CNMNT M-NET-adapter (optie)
24 CNM A-Control-Service-Tool
25 SW8
26 SW5 Functieschakelaar
27 SWP Bedrijfsstand terugzuigen
28 SW4 Testmodus
29 SW6 Modelkeuze
30 SW1 Geforceerd ontdooibedrijf, storingslijst wissen, toesteladres
31 SW7 Stapschakeling
Tabel 38 Legende van de inverter-printplaat
108


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Nefit MultiLine A-W at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Nefit MultiLine A-W in the language / languages: Dutch as an attachment in your email.

The manual is 15,28 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Nefit MultiLine A-W

Nefit MultiLine A-W Installation Guide - Dutch - 8 pages

Nefit MultiLine A-W User Manual - Dutch - 20 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info